background image

Programming

The programming is done with the button C (= Control), as well as + and -.
Programming ends if no entry is made for 10 seconds and can be ended at any point by pressing the "M" button.

Press button C briefly

Setting the heating time (1-60 minutes)

Factory settings:

The controller is delivered with the following factory settings:

target floor temperature

22°C

Frost protection temperature:

5°C

Timer / heating time

60 minutes

Pressing M and C simultaneously for 5 seconds resets the controller to the factory settings specified above.

System

To get to the system display, press the C key for 10 seconds.

Button C for 10 seconds

The current floor temperature is displayed.

The number of operating hours during which the heating
was turned on are displayed.

The software version is displayed.

Display of the room temperature
Display of the current timer time
Display both in alternation of 5 seconds

Change setting with + / - buttons

Child safety lock:

Press the + and – keys simultaneously for at least 10 seconds. The controller no longer reacts to any normal key

presses. Activation can be identified from the fact that

T

is displayed. To cancel the child safety lock, press the + and – again

simultaneously for 10 seconds.

Mains power failure:

Up to eight hours of mains power failure are compensated.

Frost protection:

The frost protection is active in all modes; it prevents the floor temperature falling below 5°C (factory setting).

Reset:

This function is normally not required, except possibly after serious mains faults.

A reset is initiated by briefly pressing the recessed key. The programmed values are maintained, but time of day and day of the week must
be set anew.

Troubleshooting:

Sensor characteristic:

Diagnosis

Possible cause / remedy

Temp. Resistance

Heating does not work 

- Connect / check mains voltage 

°C 

kΩ 

 

Display:

10

3.66

Flashing circle (left screen margin)

- Mains power failure

20

2.43

Er 1

- Room sensor defective

30

1.66

Er 2

- Floor sensor defective or not connected

40

1.15

0.0°C

- Room temperature 0°C or less

50

0.82

Press the C key briefly once