Assembly and alignment
14
2018-06-19
FM 239 MuW Beta-Typ-Z Rev.01
distributed by
6.3
Setting the maximum stroke
Risk of serious injury from overturning transport devices.
Should the carriage come to a stop beyond the safety area, the
transport device mounted on this may break off or overturn. The linear
unit can be damaged beyond repair.
Please take note of the specified safety area when setting up the unit
and set the limit switches correspondingly.
Electric switches may only be connected by a qualified electrician.
Allow for a sufficient braking distance to ensure that there is enough
time to slow down the carriage in the case of an emergency stop.
6.3.1
Adjusting the position of the inductive limit switches
The duty of the inductive limit switches is to shut down the electric drive
before the mechanical limit of travel is reached.
The necessary braking distan
ce (Δ B) depends on the speed and
deceleration. This braking distance must be less than the distance
between the trip point of the limit switch and the actual mechanical limit
of travel.
L
e
g
e
n
d
1
Inductive limit switches
2
Trip cam
3
Band marking the safety area
Figure 4: Inductive limit switches