5 Installation and commissioning
42
HSD S.p.A. © - h0104k02a.fm091115
5.5.1
Power cable with shared DC Bus
The power cable connected to the shared DC Bus for feeding a single motor must have the following
characteristics:
4x1.5 mm² + (2x1 mm²), obviously, larger sections are also allowed;
working voltage of 600/1000 V on all conductors;
80 °C;
all screening in tinned copper.
A
- outer sheath
B
- full shielding
C
- shielded 2-core cable
D
- 2-core cable shielding
E
- conductor composition 4x1.5 mm²
Always use cables with the required characteristics. For other cables, contact the
HSD Assistance Service.
In the case of power supply cables feeding two or more motors at the same time (for connections other than
star type) contact the assistance service.
Cable types
Some of the cables tested and recommended by the manufacturer are reported below.
BRAND
TYPE
MANUFACTURE
R'S CODE
HSD CODE
UNIKA
UNIDRALL 5000 4G1.5+(2X1)
11.0 / 138 / 242.8
3C047
2131A0312
FLAMAR
Cable Braid Shield Sect. 1x(2x1.00mm²
Braid 4x1.50mm²
UL Style 21223/CSA O.D. 11.00 mm
86AVSQ16xx-xxx
-
HELUKABEL 4G1.5+ 2x1.5C-C / 11.6 / 136 / 7.5xD
707481
-
Summary of Contents for CPH 400 B
Page 2: ......
Page 4: ...Information about the publication 4 HSD S p A H5834D0175 fm091115 ...
Page 8: ...Table of contents 8 HSD S p A H5834D0175TOC fm091115 ...
Page 9: ...Preliminaries ...
Page 10: ......
Page 16: ...1 Preliminary information 16 HSD S p A h0101k00a fm091115 ...
Page 20: ...2 Safety information 20 HSD S p A h0115k00a fm091115 ...
Page 21: ...Description ...
Page 22: ......
Page 50: ...5 Installation and commissioning 50 HSD S p A h0104k02a fm091115 ...
Page 51: ...Maintenance ...
Page 52: ......
Page 54: ...6 Maintenance 54 HSD S p A h0107k00a fm091115 ...
Page 55: ...Appendices ...
Page 56: ......
Page 62: ...A Technical characteristics 62 HSD S p A h0124k00a fm091115 ...
Page 64: ...B Disposal 64 HSD S p A h0109k00a fm091115 ...
Page 66: ...C Spare parts 66 HSD S p A h0111k00a fm091115 ...
Page 73: ......