34
SP 4040
11/2012
SP 4040
HSM KP 40 V
0
5.2 Baling
press
5.2.1 Hydraulic
fl uid level / venting fi lter
The hydraulic oil level must be checked at least every 3 months. Insuffi cient fl uid levels
can lead to the destruction of the unit.
Fluid level check:
– Move the press ram to its top end limit position
– Turn off the main switch and pull the mains plug out
– Unscrew the top safety cover (16)
– Unscrew the ventilation fi lter lid (12.1)
• The fl uid level can be read on the fl uid level measuring stick on the ventilation fi lter lid
• The fl uid level should be in between the two notches on the measuring stick
• If there is insuffi cient fl uid in the tank, pour more fl uid into the opening for the
ventilation fi lter lid
• Change the oil annually to increase the longevity of the hydraulic parts
– Check the ventilation fi lter lid every 3 months for dirt and blockage
– Screw the ventilation fi lter lid back in
– Mount the safety cover onto the unit again
16
12.1