e) Cleaning of the suction fan, of its location, of the lower ash collector
This must be done with a periodicity that will depend of the boilers use (amount of wood
consummation): at least 2 to 3 times per year or at least all the 13 cubic meter of wood.
Check the sealing of the silicon gasket; it must be replaced immediately if it does not work
properly.
Procedure:
Before anything else switch of the power supply.
1)
Unplug the fans electrical supply
2)
Unscrew the four nuts holding both the fan protection cover and the fan itself.
3)
Remove fan cover and fan
4)
Clean the turbine
5)
Clean the internal of the fan housing
6)
Clean the flue gas sensor pipe and the flue gas outlet itself