background image

• 7 •

With the jump starter connected to the car battery and the green LED 

illuminated on the smart cable, turn on all lights and electrical accessories for 

one minute. This draws current from the jump starter and warms the battery. 

Now try to crank the engine. If it does not turn over, repeat the procedure. 

Extremely cold weather may require two or three battery warmings before 

the engine will start.

IMPORTANT: DO NOT attempt to jump start your vehicle more 

than three consecutive times. If the vehicle will not start after three 

attempts, consult a service technician.

8.  After the engine starts, unplug the battery clamps from the jump starter 

socket and then disconnect the black clamp (-) and the red clamp (+),  

in that order. Slide the ON/OFF switch to the OFF position.

9.  Recharge the unit as soon as possible after each use.

7.2  CHARGING A MOBILE DEVICE, USING THE USB PORTS

The HSV-SPZ 189901 includes three USB ports. The standard one 

provides up to 2.4A at 5V DC. The second port is a 3A   input/output 

USB. The third port is a Quick Charge 3.0, which provides up to 5V at 

3A, 9V at 2A or 12V at 1.5A. 

1.  Consult your mobile device manufacturer for proper charging power 

specifications. Connect a mobile device cable to the appropriate USB port. 

2.  Slide the ON/OFF switch to the ON position. Charging should begin 

automatically. The display will show which port is in use.

3.  Charging time will vary, based on the mobile device’s battery size and the 

charging port used.

NOTE: Most devices will charge with any of the USB ports, but may 

charge at a slower rate. 

NOTE: The 3A   USB port requires a specific charging cable  

(not included).

4.  When finished using the USB port, disconnect the charging cable from 

your mobile device and then disconnect the charging cable from the unit. 

Slide the ON/OFF switch to the OFF position.

5.  Recharge the unit as soon as possible after each use.

NOTE: If no USB device is connected, power to the USB ports will 

automatically shut off after 30 seconds. 

7.3  USING THE LED LIGHT

1.  Slide the ON/OFF switch to the ON position.

2.  Hold down the display   button for 3 seconds.

3.  Once the LED light is on, press and release the display   button to cycle 

through the following modes:

• 

Steady glow

• 

Flash for an SOS signal

• 

Flash in strobe mode

4.  When finished using the LED light, press and hold the display   button 

until the light turns off.

5.  Slide the ON/OFF switch to the OFF position. 

6.  Recharge the unit as soon as possible after each use.

Summary of Contents for HSV-SPZ-189901

Page 1: ... THIS OWNER S MANUAL AND READ BEFORE EACH USE This manual will explain how to use the unit safely and effectively Please read and follow these instructions and precautions carefully Jump Starter MODEL HSV SPZ 189901 User Manual ...

Page 2: ...Do not expose the unit to rain or snow 1 5 Use only recommended attachments SA866 jump cable Use of an attachment not recommended or sold by the jump starter manufacturer for the HSV SPZ 189901 may result in a risk of fire electric shock or injury to persons or damage to property 1 6 To reduce the risk of damage to the electric plug or cord pull by the adaptor rather than the cord when disconnecti...

Page 3: ...ng soda nearby for use in case battery acid contacts your eyes skin or clothing 2 8 Wear complete eye and body protection including safety goggles and protective clothing Avoid touching your eyes while working near the battery 2 9 If battery acid contacts your skin or clothing immediately wash the area with soap and water If acid enters your eye immediately flood the eye with cold running water fo...

Page 4: ...tal part of the battery clips or cut the insulation of the cables 4 3 Stay clear of fan blades belts pulleys and other parts that can cause injury 4 4 Check the polarity of the battery posts The POSITIVE POS P battery post usually has a larger diameter than the NEGATIVE NEG N post 4 5 Determine which post of the battery is grounded connected to the chassis If the negative post is grounded to the c...

Page 5: ...e of charge Afully charged internal battery will read 100 Charge the internal battery if the display shows it is under 85 2 To reduce the risk of electric shock unplug the unit s charging cable from a USB or wall charger before attempting any maintenance or cleaning Simply turning off the controls will not reduce this risk 3 When charging the internal battery work in a well ventilated area and do ...

Page 6: ... clamp to the carburetor fuel lines or sheet metal body parts Connect to a heavy gauge metal part of the frame or engine block 5 For a positive grounded vehicle connect the NEGATIVE BLACK clamp from the jump starter to the NEGATIVE NEG N ungrounded post of the battery Connect the POSITIVE RED clamp to the vehicle chassis or engine block away from the battery Do not connect the clamp to the carbure...

Page 7: ...vice manufacturer for proper charging power specifications Connect a mobile device cable to the appropriate USB port 2 Slide the ON OFF switch to the ON position Charging should begin automatically The display will show which port is in use 3 Charging time will vary based on the mobile device s battery size and the charging port used NOTE Most devices will charge with any of the USB ports but may ...

Page 8: ... set to the ON position The thermometer symbol is flashing The unit is too hot or cold The thermometer symbol will disappear when the condition is removed The jump starter will not recharge Make sure the power source is live The jump starter turns on but won t jump start my vehicle Check connections Verify the charge level of the jump starter is at least 40 Do not attempt to jump start your vehicl...

Page 9: ...rnating Red and Green flashing LEDs no beep Reverse charging protection Solid Red LED Green LED off rapid beeping Short circuit protection Solid Red and Green LEDs beeps once per second Temperature protection NOTE When the condition is corrected the smart cable will automatically reset 11 SPECIFICATIONS Internal battery type Lithium ion polymer Capacity 55 5 Wh USB output Standard 5V DC 2 4A USB i...

Page 10: ...n 2 months after discovery of the non conformity Resellers Professional End User Warranty The Manufacturer provides a limited warranty for hidden defects or non conformities This warranty is subject to the following conditions a The Manufacturer only warrants hidden defects in material or workmanship present in their root cause at the moment of the first sale by the Manufacturer b Manufacturer s o...

Page 11: ...the above warranties Non authorized resellers may only sell the product under the condition that they assume all warranty obligations with the total exclusion of any warranty provided by the Manufacturer Manufacturer does not provide any warranty for any accessories used with the Product that are not manufactured by Schumacher Electric Corporation This warranty does not exclude or diminish any cla...

Page 12: ......

Reviews: