background image

“SMART Plus”

 

Electronic control for towel radiators

 

 

  

 

Rev.3 agosto 2020 

 

 

Product

 

Electronic control for towel radiators

 

Applications

 

Towel radiators

 

Insulation class

 

Classe I ClassII

 

IP level

 

IP44

 

Temperature settings

 

Digital

 

Selectable temperature range

 

14°C ÷ 29°C  -  7°C Antifreeze

 

Operational temperature

 

-10°C ÷ 40°C

 

Maximal power

 

See table below

 

Supply voltage

 

230VAC 50Hz

 

Size

 

See figure below

 

Warranty

 

2 years

 

Standards

 

-EN 60335-1:2012 -EN 60335-2-30:2011 -EN  60335-2-43:2005

 

-EN 61000-3-2:2004 -EN61000-3-3:1995 -EN  50366:2003

 

-EN 55014-1:2008 -EN  55014-2:1998

 

Approval mark

 

CE

 

Case

 

ABS-VO

 

Environmental directive

 

WEEE, RoHS

 

Electromagnetic compatibility

 

89/336/EEC

 

Operative modes

 

Comfort, Boost2h, Timer12h, Timer24h, Standby/Antifreeze, Key-lock.

 

Thermostat status indicator

 

Boost/Timer LED (red/green/amber).

 

Comfort Bar with 6 LEDs: 1 blue, 1 green, 2 yellows, 2  reds

 

Connection to mains

 

3 Cables (neutral, live, earth); Italian plug; Swiss plug: UK plug:; Schuko 
plug ;  2  Cables (neutral, live,).

 

Available colors

 

White (RAL 9003); Chrome.

 

Max. temperature  of the thermalfuse

 

152°C

 

 
 
 

 

  

 

 

Power

 

(W)

 

100

 

200

 

300

 

400

 

500

 

600

 

700

 

800

 

900

 

1000

 

Energy density

 

(W/Cm

2

)

 

1.5

 

2.9

 

4.0

 

4.1

 

4.1

 

4.1

 

4.0

 

4.0

 

4.0

 

4.0

 

L

(heating element)

 

(mm)

 

350

 

350

 

370

 

430

 

450

 

560

 

630

 

700

 

760

 

830

 

 

Summary of Contents for SMART Plus

Page 1: ...d temperature The temperature is however automatically controlled in order not to exceed 29 C At the end of the 2 hours period the device returns to Comfort mode Timer mode The control system enters into Boost mode for 2 hours after that it returns into Comfort mode for 22 or 10 hours period configurable by the user and then it enters again into Boost mode for 2 hours This sequence is repeated end...

Page 2: ...N 50366 2003 EN 55014 1 2008 EN 55014 2 1998 Approval mark CE Case ABS VO Environmental directive WEEE RoHS Electromagnetic compatibility 89 336 EEC Operative modes Comfort Boost2h Timer12h Timer24h Standby Antifreeze Key lock Thermostat status indicator Boost Timer LED red green amber Comfort Bar with 6 LEDs 1 blue 1 green 2 yellows 2 reds Connection to mains 3 Cables neutral live earth Italian p...

Page 3: ...ating element Any other use is forbidden Before using carefully ensure that the line voltage is the same as that specified for the device see technical specifications Only use heating elements compatible with the type of used towel radiator Disconnect power supply before cleaning or before performing maintenance of theproduct In case of damage of the power supply cable shut down the device and do ...

Page 4: ...ntal torsion to perfectly align the thermostat with the radiator 4 Tilt the radiator as in fig 3 making sure that the opening on top of the radiator is located on the highest side WARNING Do not lean the radiator on the electronic control 5 Fill the radiator with the specific liquid 6 Put the radiator back in vertical position and check the internal level of the liquid fig 4 7 Ensure a proper fast...

Page 5: ...ing on the radiator and buttons For setting the desired temperature Boost Timer Button To select one of Boost Timer12 and Timer24 modes Comfort bar Boost Timer Led Small red green amber light indicator to inform about the active mode Power cord External NTC sensor Used for automatic temperature control 15 5 C 14 C 7 C Blinking LED 18 5 C 17 C 20 C 21 5 C 23 C 24 5 C 26 C 27 5 C 29 C Rev 3 agosto 2...

Page 6: ... blinking LED in the Comfort bar indicates the selected temperature see table and figures below Examples First configurable Comfort temperature 14 C Press once the button The configured temperature is of 18 5 C first yellow LED blinking Press 4 times the button The configured temperature is of 23 C second yellow LED permanently lit Press 7 times the button Antifreeze temperature Standby mode In th...

Page 7: ...of the Comfort mode is of 21 hours Timer24 indication During 2hrs Boost Boost Timer LED blinkinggreen During 22hrs Comfort Boost Timer LED permanent green Timer12 mode Press the Boost Timer button for more than 5 seconds to activate it The control system activates the Boost mode for 2 hours after that it returns into Comfort mode and after 10 hours the Boost mode is started again for 2 hours This ...

Page 8: ...id inadvertent modifications of the settings Press together the and buttons for 3 seconds to lock all the buttons except the On Standby button To unlock the buttons press again together the and buttons buttons for 3 seconds When key lock is activated the device beeps twice When key lock is deactivated the device beeps four times Additional indications provided by the Comfort Bar The two central ye...