background image

Set to “OFF” if:

You will NOT turn zones on and off using the zone buttons

AND

You are utilizing impedance matching volume controls to adjust the overall system impedanc

e

Note: it is ok to daisy-chain a second speaker selector using the connectors labeled “OUTPUT” when the protection switch is “OFF” and you are utilizing a planned system 

of impedance matching.  Connecting the “OUTPUT” of one speaker selector to the “INPUT” of a second speaker selector creates a “parallel” connection.

Warranty

All HTD electronics carry a two-year parts and labor warranty.  Warranty registration occurred automatically 

at the time your order was placed.  There is no need to complete or mail in additional paperwork.

Setting the Protection Circuit

Set to “ON” if:

You plan to turn zones on and off using the zone buttons

AND/OR

You are NOT using impedance matching volume controls

Note: do NOT daisy-chain multiple speaker selectors (using the connectors “OUTPUT”) when setting the protection switch to “ON”

PROTECTION

CIRCUIT
SWITCH

OFF           ON

If you have any questions, we can be reached at...

info@htd.com or toll free 1-866-HTD-AUDIO (483-2834)

Stereo Amplifier

Speaker Selector

Impedance

Match X4

Speaker Outputs

R

 

L

+

-

-

+

Impedance

Match X4

Impedance

Match X4

Zone 2

Zone 1

Zone 3

Impedance Matching 

Stereo Volume Control

Stereo Amplifier

Speaker Selector

*

 Stereo Volume Control

Speaker Outputs

R

 

L

+

-

-

+

Zone 2

Zone 1

Zone 3

**

 Stereo Volume Control

*

 Stereo Volume Control

If using impedance matching 

stereo volume controls:
  

*

 = set to X1

**

 = set to X2

2nd pair only pos-

sible with impedance 

matching stereo 

volume control set 

to X2

Impedance Matching 

Stereo Volume Control

Impedance Matching 

Stereo Volume Control

PROTECTION

CIRCUIT
SWITCH

OFF           ON