background image

Don’t weld the battery without permission.

Such operation may damage the battery and result in leakage and 
explosion of the battery.

Avoid that the battery is impacted (such as collusion and
falling, etc).

Such condition may damage the battery case or result in that the 
battery leaks or explode.

Please pull off the adapter on the power socket when charging is 
not made.

The adapter may get overheated if it is connected with power supply 
for a long time. This may cause overheating, deformation and fire.

When the plug of the adapter or wire is damaged, stop using
immediately.

Don’t change the battery unless the plug of the charger is inserted into 
the socket completely.

Please ensure that the plug of the adapter is inserted into the 
specified power socket.

The adapter plug may be different due to the regions. Please make 
confirmation whether the specification of the adapter is consist with the 
specification of electric appliances in your region. Otherwise, this may 
cause overheating of the equipment, electric shock, fire, chemical 
leakage inside the battery, explosion and other serious consequences.

Do not touch the electric wire with wet hands.

It is possible to cause electric shock when touching the electric wire 
with wet hands. When pulling out the electric wire, hold the electric wire 
head rightly to pull out the wire. Don’t pull off the electric wire directly. 
Otherwise, the electric wire may be broken, causing electric shock and 
fire.

Forbid dip the product into water caught in rain.

If the case contact with any liquid, please wipe it dry immediately. If 
water or other liquid enters the inside of the instrument, please power 
off the power supply at once. Continuous use may result in product 
damage.

Clean the dust on the adapter plug and the data line.

When it is exposed to dusty and dump environment for a long time, the 
dirt surrounding the electric equipment will accumulate moisture. This 
may cause short circuit and fire.

 Please use the original adapter of the company to charge the
product.

The use of non-original power supply accessories may cause 
equipment overheating, electric shot, fire, and leakage of chemicals 
inside the battery,explosion and other serious consequences.

 Don’t use abradant, isopropanol or solvent to clean the enclosure 
of the device.

Such operation may cause the product case to be damaged.

www.xintest.com.cn

5

www.xintest.com.cn

6

Summary of Contents for HT-19+

Page 1: ...1 0 May 12 2021 Dongguan Xintai Instrument Co Ltd Add Building F No 13 16 Hongye Industrial Zone Tangxia community Tangxia Town Dongguan City Postcode 523710 Tel 86 769 82612006 Fax 86 769 82612005 Website www hti meter com https hti instrument com www xintest en alibaba com HT 19 ...

Page 2: ...f Image overlapping 2 Introduction to images sub menu 2 1 View image 2 2 Delete images 3 Video sub menu 3 1 View video 25 26 27 28 29 30 30 32 30 30 31 33 31 26 30 3 2 Delete video 4 Introduction to color palette sub menu 4 1 Color palette description 4 2 Application of color palette 5 Introduction to emissivity sub menu 5 1 Emissivity description 5 2 Emissivity setting 5 3 The emissivity value of...

Page 3: ... Xintai Instruments and Apparatus Co Ltd to obtain the authorization information for return Then post the product together with problem description to the service center with postage and insurance expenses prepaid Our company will not undertake any responsibility for any damage occurred during the process of transportation The product will be posted to the purchaser after repair with the transport...

Page 4: ...ge the product Don t assemble or dismantle the product without permission The product is a type of super precise equipment Don t try to dismantle assemble or remodel any part of the product Repair of the product should be made by technical personnel designated by Xintai Company Avoid damage to probe of the product Note don t put the product close to strong heat source directly such as electric iro...

Page 5: ...ous consequences Do not touch the electric wire with wet hands It is possible to cause electric shock when touching the electric wire with wet hands When pulling out the electric wire hold the electric wire head rightly to pull out the wire Don t pull off the electric wire directly Otherwise the electric wire may be broken causing electric shock and fire Forbid dip the product into water caught in...

Page 6: ...se power it off immediately Otherwise the instrument may be damaged Operation is not allowed unless the water condensation disappears For a long time infrared thermal imaging detection technology has become an important means to ensure Industrial safety in developed countries The application field includes electric power metallurgy petro chemistry machinery coal traffic fire control and national d...

Page 7: ... professional optical glasses Lens maintenance Prevent damage of the infrared lens Clean the lens The following major functions increase the product s accuracy and usability The radiation coefficient may be adjusted to increase the measurement accuracy of objects with half reflection surface The highest temperature and lowest temperature cursor may guide the users to the areas with highest and low...

Page 8: ...evel is low the top right of the screen will display Please charge in time through Micro USB interface When the product is off you can charge www xintest com cn 11 www xintest com cn 12 Infrared image resolution Visible image resolution LCD resolution Field angle Minimum focusing distance Thermal sensitivity Temperature measurement range Measurement accuracy Emissivity Frame rate of thermal images...

Page 9: ...t Automatic power off time Power supply Product size Product weight Work temperature Storage temperature Relative humidity Working time Built in chargeable 18650 battery Selectable 5 minutes 20 minutes not power off automatically 90mm 105mm 223mm 389g 0 to 45 20 to 60 85 RH 2 3 hours JPG Setting command Language Unit language date time information USB Micro USB 2 0 ...

Page 10: ...Visible light camera Infrared imaging sensor Image capture key Battery Cap Micro USB Please open the cap in use Please open the cap in use 2 3 www xintest com cn 15 www xintest com cn 16 ...

Page 11: ... screen area It will move with the movement of the highest temperature The cursor displays red The temperature value is displayed at bottom left corner of the screen The lowest temperature cursor used to indicate the lowest temperature position in the screen area It will move with the movement of the lowest temperature The cursor displays red The temperature value is displayed at the central posit...

Page 12: ... to confirm that the image is not saved Record video Long press the image capture button the screen will prompt record video if you select Yes at this time please press the MENU button or short press the image capture button to start recording Press the ENTER key or long press the image capture key to end the recording If you choose No please press the SELECT button to confirm not to record video ...

Page 13: ...issivity and Settings submenus Press the MENU button to enter the main menu and select images in the main menu Image overlapping makes it easier for users to understand the infrared images by using aligned visible images and infrared images The use of image overlapping can capture the visible image of every infrared image so as to display the temperature distribution in the target region correctly...

Page 14: ... low temperature But the black white and white black color palettes provide even linear color Iron oxide red Rainbow Cold color White heat Black heat www xintest com cn 23 www xintest com cn 24 L 5 L 5 L 5 5 L 5 3 Video sub menu 3 1 View video 3 2 Delete video Press the key to enter the video list press the keys in the navigation keys to select a video and then press the SELECT key to view the vid...

Page 15: ... to obtain relatively correct measurement value The emissivity is usually set as 0 95 when the coarse objects that are easy to give out energy For semi matte objects that give out less energy the emissivity is usually about 0 85 and the emissivity of semi gloss objects is 0 6 The shiny objects are divided into materials with low radiation coefficient The emissivity is usually set as 0 3 at the tim...

Page 16: ...alue through the self define option please refer to the table of emissivity of common materials Thermal radiation Black cloth Human skin Foam Charcoal dust Paint Matte paint Black rubber Plastic Timber Paper Chromium hemitrioxide Copper oxide Ferric oxide Textile Substance Thermal radiation Substance Bitumen Concrete Cement Sand Earth Water Ice Snow Glass Ceramics Marble Gypsum Mortar Brick If you...

Page 17: ...n or 5 points The clock is turned off or turned off in 20 minutes After selecting intensity press the button in the navigation key to enter the brightness setting Can be set to low or medium or bright 6 3 Language settings 6 4 Unit setting www xintest com cn 29 www xintest com cn 30 Settings Auto shutdown Auto shutdown Intensity Language Unit Time Format Year Month Day Hour Minute Second Set time ...

Page 18: ...ot press the button in the navigation key to enter the cold hotspot setting As shown in the figure after selecting set time press in the navigation key to enter the setting time Press key to select off or on the option Then press SELECT key to determine selection After the setting is completed press key to return Press MENU key to exit from the menu www xintest com cn 31 www xintest com cn 32 Afte...

Page 19: ...The thermal imaging device powers off automatically No thermal images The lens cover is not opened Open the lens cover Failure cause The battery is not installed The power of the battery is used up Solution Install the battery Replace with new battery or charge it The power of the battery is used up Replace with new battery or charge it The time set for automatic power off is due Restart or change...

Reviews: