10
Pressure Relief Valve (Part #7250P-219 for EL80/110/150, #7350P-065 for EL220/299/399)
Indirect Sensor
Outdoor Sensor
Intake PVC Tee with Screens
Exhaust PVC Coupling with Screens
Outlet Combination Fitting (
1” - Part #7450P-134 for EL80/110/150/220, 1.25” - #7450-135 for EL299,
1.5” - #7450-136 for EL399)
Installation Manual
Warranty
CSD-1 Form
H-3 Data Sheet
NAT to LP Conversion Kit (Part #7450P-223) (Included with NAT models)
LP to NAT Conversion Kit (Part #7450P-224) (Included with LP models)
B. HOW BOILER OPERATES
Elite
®
condensing technology intelligently delivers hydronic heating while maximizing efficiency. Outlined below
are the features of the system and how they operate:
Stainless Steel Heat Exchanger
- The highly efficient stainless steel heat exchanger is designed to extract all
available heat from the supply line before it is exhausted.
Modulating Combustion System
- The combustion system will modulate the output of the burner during
operation to match the system demand and achieve the control set point while in operation. The set point can
change by internal or external signals which enhance the overall performance of the system.
Control
– The integrated control system monitors the system and regulates fan speed to control boiler output.
This allows the boiler to deliver only the amount of heat energy required and nothing more.
The control can be set up to monitor outdoor temperature through an outdoor sensor to regulate boiler set point.
The system can be further enhanced by installing an indirect water heater to provide domestic hot water.
The control can regulate the output of multiple boilers through its cascade system function. The cascade system
is capable of connecting up to eight boilers together in such a way that they function as one boiler system. This
allows for greater turn down ratios and provides systematic control of the multiple boilers in an installation to
minimize downtime and maximize efficiency.
The cascade system works by establishing one boiler as the master and the other connected boilers as followers.
The master boiler requires a sensor to provide feedback on set point temperature in order to adjust heating input
from the connected boilers. Each cascaded boiler will have its own pump to provide maximum flow and control
heat exchanger flow rate.
Text Display and Operational LED Light Indicators
– The display allows the user to change system
parameters and monitor system outputs.
Gas Valve
– Senses suction from the blower, allowing gas to flow only if powered and combustion air is flowing.
All Metal Integrated Venturi
– Controls air and gas flow into the burner.
Burner
– Constructed of high grade stainless steel, the burner uses premixed air and gas fuel and provides a
wide range of firing rates.
Spark Ignition
– The burner is ignited by applying high voltage through the system spark electrode. This causes
the spark from the electrode to ignite mixed gas off of the burner.
Summary of Contents for EL-110
Page 15: ...15 Figure 3 ...
Page 61: ...61 Figure 29 ...
Page 62: ...62 Figure 30 ...
Page 87: ...87 Figure 33 ...
Page 88: ...88 Figure 34 ...
Page 89: ...89 Figure 35 LP 293 A NOTE Parts listed on the following page ...
Page 94: ...94 ...
Page 95: ...95 ...
Page 96: ...96 MAINTENANCE NOTES ...