11
Supply Water Temperature Sensor
– This sensor monitors the boiler outlet water temperature (System Supply).
The control adjusts the boiler firing rate so the supply temperature will match the boiler set point.
Return Water Temperature Sensor
– This sensor monitors the boiler return water temperature (System Return).
Flue Sensor
– Monitors flue temperature and adjusts firing rate.
Temperature and Pressure Gauge
– Allows the user to monitor system temperature and pressure.
Electrical field connections with terminal strips
– The electrical cover allows easy access to the line voltage
and low voltage terminals strips which are clearly marked to facilitate wiring of the boiler.
Condensation Collection System
– This boiler is a high efficiency appliance, therefore the boiler will produce
condensate. The collection system has a float switch which monitors the condensation level and prevents
condensation from backing up into the combustion system. Inside the collection system there is a built in trap
which seals the combustion system from the connected drain. This condensate should be neutralized to avoid
damage to the drainage system or piping.
Outdoor Sensor
– Monitors outdoor temperature and adjusts unit set point to provide greater efficiency.
0-10 Volt Input
– Allows Installer to connect a BMS (Building Management System) to control the boiler.
Condensate Flue Check System
– The check system prevents exhaust from the heat exchanger from backing
up into cabinet.
Pump Service Mode
– Allows manual operation of pumps to commission system and check pump operation.
The Vision II System
(Optional)
– Allows the user to supply mixed temperatures in up to eight zones. The Vision
II system controls the temperature to each zone by employing three way mixing valves. The Vision II also controls
the output temperature of the boiler to assure accurate temperature delivery to all connected zones.
C. OPTIONAL EQUIPMENT
Below is a list of optional equipment available from HTP. These additional options may be purchased through
your HTP distributor:
Wall Mount Bracket (Part # 7450P-211)
System Sensor (Part # 7250P-324)
Indirect Tank Sensor (Part # 7250P-325)
3" PVC Concentric Vent Kit (Part # KGAVT0601CVT)
3” Stainless Steel Outside Termination Vent Kit (Part # V1000)
4” Stainless Steel Outside Termination Vent Kit (Part # V2000)
6” Stainless Steel Outside Termination Vent Kit (Part # V3000)
3” Polypro Vent Kit (Part # 8400P-001)
3
” Polypro Pipe (33’ length Part # 8400P-002, 49.5’ length Part # 8400P-003)
U.L. 353 Compliant Low Water Cut-Off Interface Kit with Manual Reset (Part # 7450P-225)
Manual Reset High Limit (Part # 7450P-217)
Alarm System (Part # 7350P-602) (to monitor any failure)
PC Connection Kit (Part # 7250P-320)
Condensate Neutralizer (Part # 7450P-212 for EL-80/110/150/220/299, Part # 7350P-611 for EL-399)
Flow Switch Kit (Part # 7450P-213 for EL-80/110/150/220, Part # 7450P-214 for EL-299, Part # 7450P-
215 for EL-399)
Vision II (Part # 7250P-322)
Summary of Contents for EL-110
Page 15: ...15 Figure 3 ...
Page 61: ...61 Figure 29 ...
Page 62: ...62 Figure 30 ...
Page 87: ...87 Figure 33 ...
Page 88: ...88 Figure 34 ...
Page 89: ...89 Figure 35 LP 293 A NOTE Parts listed on the following page ...
Page 94: ...94 ...
Page 95: ...95 ...
Page 96: ...96 MAINTENANCE NOTES ...