Maintenance Notes

Summary of Contents for Elite

Page 1: ...t warranty and cause property damage severe personal injury or death IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED EXACTLY A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE PERSONAL INJURY OR LOSS OF LIFE DO NOT STORE GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS INTHEVICINITY OFTHIS OR ANY OTHER APPLIANCE WHATTO DO IFYOU SMELL GAS Do not try to light any appliance Do not touch any elect...

Page 2: ...serious personal injury or death WARNING indicates a potentially hazardous situation which if not avoided could result in personal injury or death CAUTION indicates a potentially hazardous situation which if not avoided may result in moderate or minor personal injury CAUTION used without the safety alert symbol indicates a potentially hazardous situation which if not avoided may result in property...

Page 3: ... IN SUBSTANTIAL PROPERTY DAMAGE SEVERE PERSONAL INJURY OR DEATH A Appliance Operation Do not block flow of the appliance exhaust vent or intake pipe Should overheating occur or gas supply fail to shut off do not turn off or disconnect electrical supply to the circulator Instead shut off the gas supply at a location external to the appliance following the instructions on page 2 Do not use this appl...

Page 4: ...k appliance water pressure piping and expansion tank Check control settings Check ignition electrode Sand off any white oxide Clean and reposition Check ignition and ground wiring Check all control wiring and connections Check burner flame pattern stable and uniform Additional Items if Combustion of Performance is Poor Clean heat exchanger and flue ways Remove burner assembly and clean burner head...

Page 5: ...tructions Remove any debris from the exhaust vent and intake pipe openings If removing the debris does not allow the appliance to operate correctly contact your qualified service technician to inspect the appliance and the vent system CheckTemperature Display and Pressure Gauge Ensure the pressure reading on the gauge does not exceed25psigonboilermodels 145psigonVWHmodels Higher pressure readings ...

Page 6: ...ns or property damage should the valve discharge Read the temperature and pressure gauge to ensure the system is pressurized Minimum is 10 psi Maximum is 25 psig for boilers 145 psig for VWH models Lift the relief valve top lever slightly allowing water to relieve through the valve and discharge piping If water flows freely release the lever and allow the valve to seat Watch the end of the relief ...

Page 7: ...LP 389 Rev 6 3 15 7 Maintenance Notes ...