5

Figure 1 - Recommended Service Clearances 

3" MIN.

3" MIN.

3" MIN.

24" MIN.

LP-790-B

10/04/21

8" MIN.

RECOMMENDED SERVICE CLEARANCES

This water heater must not be located near flammable liquids 

such as gasoline, butane, liquefied propane, adhesives, solvents, 

paint thinners, etc., as the controls of this water heater could 

ignite these vapors and cause an explosion resulting in property 

damage, severe personal injury, or death.

4. If the water heater is to replace an existing water heater, check for 

and correct any existing system problems such as:

•  System leaks
•  Location that could cause the system and water heater to 

freeze and leak

•  Incorrectly-sized expansion tank

5. This water heater must be installed vertical on a level surface.

C. Water Chemistry Requirements

Chemical imbalance of the water supply may affect efficiency and 

cause severe damage to the appliance and associated equipment. 

Water quality must be professionally analyzed to determine 

whether it is necessary to treat the water. Various solutions are 

available to adjust water quality. Adverse water quality will affect 

the reliability of the system. In addition, operating temperatures 

above 135

o

F will accelerate the build-up of lime scale and possibly 

shorten appliance service life. Failure of an appliance due to 

lime scale build-up, low pH, or other chemical imbalance IS NOT 

covered by the warranty.

The water must be potable, free of corrosive chemicals, sand, 

dirt, and other contaminates. It is up to the installer to ensure the 

water does not contain corrosive chemicals or elements that can 

damage the heat exchanger. Potable water is defined as drinkable 

water supplied from utility or well water in compliance with EPA 

secondary maximum contaminant levels (40 CFR Part 143.3). If 

the water contains contaminants higher than outlined by the EPA, 

water treatment is recommended and additional, more frequent 

maintenance may be required.
If you suspect that your water is contaminated in any way, 

discontinue use of the appliance and contact an authorized 

technician or licensed professional.

Failure of electric elements due to lime scale build-up on the heating 

surface, low pH, or other imbalance IS NOT covered by the warranty.

•  Water pH between 6.5 and 8.5

•  pH levels below 6.5 can cause an increase in the rate of 

corrosion. pH of 8.5 or higher can potentially cause lime 

scale build-up

•   Maintain water pH between 6.5 and 8.5. Check with litmus 

paper or have it chemically analyzed by a local water 

treatment company.

•  If the pH is not between 6.5 and 8.5, consult a local water 

treatment company for solutions.

•  Hardness less than 12 grains (200 mg/L)

•   Hardness levels above the required amounts can lead to lime 

scale build-up throughout the system. Water below 5 grains/

gallon (85 mg/L) may be over softened.

•  Consult local water treatment companies for unusually 

hard water areas (above the required amounts) or for other 

treatment solutions if water is being over softened (below 5 

grains/gallon [85 mg/L]).

•  Chloride concentration less than 100 ppm (mg/L)

•   Do not fill appliance or operate with water containing 

chlorides in excess of 100 ppm (mg/L). 

•  Using chlorinated fresh water should be acceptable as levels 

are typically less than 5 ppm (mg/L).

•  Do not connect the appliance to directly heat swimming 

pool or spa water.

•  Total Dissolved Solids (TDS) less than 500 ppm (mg/L)

•   Total dissolved solids are minerals, salts, metals, and charged 

particles that are dissolved in water. 

•  The greater the amounts of TDS present, the higher the 

corrosion potential due to increased conductivity in the 

water.

•  If using softened water to fill the appliance, it is still possible 

to have high TDS. This water can be corrosive. Consult local 

water treatment companies  for other treatment solutions to 

reduce this affect.

*NOTE:

 To promote appliance service life, it is strongly recommended 

to follow the maintenance procedures in this manual.

Summary of Contents for Everlast Elevate ELV055C2X055N

Page 1: ...held liable for typographical errors in literature NOTE TO CONSUMER PLEASE KEEP ALL INSTRUCTIONS FOR FUTURE REFERENCE 272 Duchaine Blvd New Bedford MA 02745 www htproducts com lp 790 Revision Date 1 3 22 The surfaces of these products contacted by potable consumable water contain less than 0 25 lead by weight as required by the Safe Drinking Water Act Section 1417 Use and Care Manual California Pr...

Page 2: ...ls 3 Install or locate this water heater only in accordance with the provided installation instructions 4 Use this water heater only for its intended use as described in this manual 5 Do not operate this water heater if it has been damaged or dropped 8 This water heater should be serviced only by qualified service personnel Contact the water heater installer or a qualified service agency for exami...

Page 3: ...ent and ECO Reset 11 C Adjusting the Tank Booster 12 D Heating Element Replacement Procedure 12 Part 7 Maintenance 14 Part 8 Troubleshooting 16 Part 9 Replacement Parts 17 Limited Warranty 18 Customer Installation Record Form 20 Do not use this water heater for anything other than its intended purpose as described in this manual Doing so could result in property damage and WILL VOID product warran...

Page 4: ...n 32oF 0oC and lower than 104oF 40oC Avoid continuously high levels of humidity Never close existing ventilation openings NOTE When installing in a zero clearance location it may not be possible to read or view some product labeling It is recommended to make note of the water heater model and serial number NOTE A combustible door or removable panel is acceptable front clearance Theservicelifeofthe...

Page 5: ...er treatment is recommended and additional more frequent maintenance may be required If you suspect that your water is contaminated in any way discontinue use of the appliance and contact an authorized technician or licensed professional Failure of electric elements due to lime scale build up on the heating surface low pH or other imbalance IS NOT covered by the warranty Water pH between 6 5 and 8...

Page 6: ...d Temp Max Del Temp Min Del Temp Max Del Temp High Temp Limit ELV055C2X055N 55 6 3 4 41 1 2 51 58 23 1 4 8 3 4 NPT 150 90oF 32 C 130o F 54 C 125oF 51 7 C 170o F 76 7 C 190o F 87 8 C Table 2 Specifications and Dimensions See Table 3 for Electrical Specifications Model Safety Listing Elements and Thermostats Available Wattage Voltage Full Load Current in Amps Single Phase ELV055C2X055N UL 174 2 5 50...

Page 7: ...elief valve causing it to operate during each heating cycle resulting in discharge from theT P This rapid and repeated expansion and contraction of components in the system can cause premature failure of system components including the relief valve and possibly the water heater Replacing the relief valve will not correct thermal expansion A potable hot water expansion tank is required to offset th...

Page 8: ...LT IN PROPERTY DAMAGE SERIOUS PERSONAL INJURY OR DEATH Do not thread a cap or plug into the relief valve or block relief valve outlet line under any circumstances Explosion and property damage serious injury or death may result C Condensation Condensation can form on the water heater when it is first filled with water and may also occur with a heavy water draw and very cold inlet water temperature...

Page 9: ...ler water to clear the system Follow the instructions in this manual if thermostat or mixing valve need adjustment Failure follow these instructions could result in property damage severe personal injury or death due to scalds Make certain that the drain valve is completely closed Open the shut off valve in the cold water supply line Open the hot water faucets to allow air to vent from the heater ...

Page 10: ...ved conduit and fittings or other approved conductive material A grounding wire is provided on the junction bracket This grounding wire must be used in the installation Tank must be full of water before the power is turned on Heating elements will be damaged if energized for even a short time while tank is dry Failures due to dry firing ARE NOT covered by warranty Be sure to ground the water heate...

Page 11: ...erature becomes excessively high the ECO breaks the circuit to the heating element Once the switch opens it must be reset manually However THE CAUSE OF THE OVER TEMPERATURE CONDITION MUST BE CORRECTED FIRST The cause of the high temperature condition must be investigated by a qualified service technician and corrective action must be taken BEFORE placing the water heater back in service Failure to...

Page 12: ...eater from the system Drain the water from the system or just the water heater if it can be isolated from the system If heating elements need replacement it is very important to use the same voltage wattage and construction DO NOT replace heating element with a generic heating element Only HTP heating elements are approved for use with this water heater Failure to follow this warning will result i...

Page 13: ...ent STEP 7 Screw the element clockwise into the tank and tighten with the 1 1 2 socket wrench or element tool Be sure gasket seats properly NOTE Repeat Steps 3 6 as Necessary for Multiple Elements Step 8 Open the main cold water inlet If the water heater has been isolated from the system open the valves Refill the tank with cold water Open a hot water faucet high in the system to bleed any air pre...

Page 14: ...il it cools BEFORE draining water from the heater Failure to comply with this warning could result in property damage severe personal injury or death hot water is needed again Contact a qualified service contractor for assistance if necessary Water drained from the water heater may be scalding hot Take care to avoid scalding Wear gloves and safety glasses and direct water to a safe drainage locati...

Page 15: ...and System STEP 1 Open a hot water tap high in the system to bleed any air pressure Water will flow freely when air is completely bled STEP 2 Open the main cold water inlet If the water heater has been isolated from the system open the isolation valves Refill the tank with cold water STEP 3 Close the tap when air is completely bled from the system and water is flowing freely Check the water heater...

Page 16: ...ork Check wiring or replace thermostat Water Too Hot or Not Hot Enough Thermostat or Mixing Valve setting too high or low Change setting as required Thermostat out of calibration Replace thermostat Thermostat access panel s and or insulation not in place Inspect and replace as needed Thermostat s not resting tightly against mounting plate Ensure that retaining spring s or mounting screws hold ther...

Page 17: ... 55 GAL 6060P 502 9 JUNCTION BOX COVER W SCREWS 6060P 983 10 JUNCTION BOX COVER W KNOCKOUTS W SCREWS 6060P 982 11 TEMP PRESSURE RELIEF VALVE TP1000 12 ALUMINUM ANODE 63 DIA X 12 LENGTH 1 1 16 SOCKET 6060P 008 13 MOUNTING BRACKET 6060P 955 14 ELECTRIC ELEMENT 5500W 6060P 937 15 UPPER THERMOSTAT 6060P 085 16 UPPER THERMOSTAT PROTECTIVE COVER 6060P 994 17 PROTECTIVE INSULATION 6060P 965 18 ACCESS PAN...

Page 18: ...rranty detailed above F This warranty extends only to water heaters utilized in water heating applications that have been properly installed by qualified professionals based upon the manufacturer s installation instructions G It is expressly agreed between HTP and the Owner that repair replacement or refund are the exclusive remedies of the Owner OWNER RESPONSIBILITIES The Owner or Qualified Insta...

Page 19: ...ng a Serial number tag sticker b The product c The product issue failure whenever possible d A picture of the piping near the product e For gas fired products a picture of the venting including how it exits the building All claims will be reviewed by HTP within three 3 business days If additional information is required and requested by the HTP Claims Department you will have thirty 30 days to pro...

Page 20: ...ation Installation Address Product Name Serial Number s Comments Installer s Code Name Installers Phone Number Signed by Installer Signed by Customer Installation Notes IMPORTANT Customer Please only sign after the qualified installer service technician has fully reviewed the installation safety proper operation and maintenance of the system If the system has any problems please call the qualified...

Reviews: