29
30
LP-532 REV. 8.13.2014
LP-532 REV. 8.13.2014
Description/Part #
Gas Valve / 7850P-012
Check Point
(Main PCB)
CN9
Function
Negative gas valve controls the regulation of gas and air mixture in the combustion
system.
Failure Event
① Gas leakage occurs.
② Gas valve does not operated. (Unable to open/close)
③ Gas flow is not modulated. (Proportional gas valve)
Effects
① Spark is not generated..
③ Operation of product is stopped.
④ Carbon monoxide exceeding the reference is discharged.
Error Code
Er 10
Diagonostic
① Check wiring for proper connection.
② Check the connection and mounting location.
③ Check resistance by using a multimeter.
Color / Wire Number
Gas Valve (purple) : connector ⑥, ⑫
Description/Part #
Air Gas Mixer / 7850P-004
Check Point
(Main PCB)
CN12
Function
The component provides proper air and gas mixture to the burner.
Failure Event
① Imperfect combustion occurs.
② lifting flame occurs.
Effects
① Abnormal product operation.
② Carbon monoxide exceeding the reference.
Error Code
Er 67
Diagonostic
① Restart the water heater.
② Check wiring for proper connection.
③ Check the fan intake.
Color / Wire Number
Air Gas Mixer (black) : ①
connector (
AGM/Y Phase)
Air Gas Mixer (brown) : ②
connector (
AGM/Y Phase)
Air Gas Mixer (red) : ③
connector (
AGM/X Phase)
Air Gas Mixer (orange): ④
connector (
AGM/X Phase)
Air Gas Mixer (yellow) : ⑤
connector
(GND)
Air Gas Mixer (green) : ⑥
connector (AGM Position Sensor)
Air Gas Mixer (white) : ⑦
connector (DC 24V)
1. Operating Temperature : 32~140 F
2. Using the gas pressure : 5 kPa
3. Maximum amount of gas: 5.5m3/hr (LNG)
4. T/D(Turn/Down ratio) : 1 : 10
5. Motor Specification
- Type : Stepping Motor
- Phase : 4 Phase
- Drive type : Unipolar Drive / V-Constant
- Supply Power : 24v DC
- Phase excitation system : 2-2
- Step angle : 7.5 deg(2-2Phase), (1-2 Phase : 3.75 deg)
- Direction of rotation : CW / CCW (Bidirectional)
- Reduction ratio : 1 / 60
1. Backpressure
: 1st valve: 50 mbar
: 2nd valve: 10 mbar
2. Ambient temperature:
: -15℃ ... 70°C (5 ~ 158℉)
3. Max inlet pressure: 60 mbar
4. Operating Ratings: 24 V /50 Hz
5. Electrical Load
: 1st + 2nd operator 420mA at 24 V RAC
① ② ③ ④ ⑤ ⑥ ⑦
①
②
③
④
⑤
⑥
⑦
⑧
⑨
⑩
⑪
⑫
Chapter 2 Components description
Chapter 2 Components description
CN12
CN9