69
70
LP-532 REV. 8.13.2014
LP-532 REV. 8.13.2014
Error code
Meaning
Cause
Jumped wire disconnected
(Manual reset)
Er 42 will appear if wire is
disconnected.
Failure event
Jumped wire disconnected.
Check point
① Ensure that jumped wire is properly connected on the main
controller.
② If all things are normal, replace main controller.
Chapter 4 Troubleshootion
Error code
Meaning
Cause
Burner plate overheating
protection switch open
(Manual reset)
If burner temperature is higher
than the switch high limit (302 F),
error code 43 will appear.
Failure event
When burner overheating switch's temperature exceeds 392 F, error code will appear.
Check point
② Check to see if the default DIP SWITCH settings
have been changed from the factory settings – assure
that default settings are set to correct overheating
condition.
③ When all the things are normal
check gas nozzle. Check assembly
condition of burner and heat exchanger.
① Check burner plate for
distortion or burn marks.
If plate shows signs of
overheating, replace entire
burner plate assembly.
Chapter 4 Troubleshootion
WARNING
Failure to turn the power off to the appliance before repair could result in serious injury or death.
WARNING
Failure to turn the power off to the appliance before repair could result in serious injury or death.