63
Figure 27
10. Press and hold
ENTER
for 4 seconds until you see the screen to log in the access code.
11. Use the
and
arrow keys to move the blinking zero to the left and right. Next, use the
▲
and
▼
arrow keys on to log in the access code of 925. Press
ENTER
to access the
System Setting Program
Navigation
menu. Once the code is confirmed, you can set the
System Settings
. Use
and
to
navigate through the
System Setting Program
.
12. Press
3 times to scroll to Function 4 - “WARM WEATHER OFF”. This is the warm weather
shutdown. This function determines the outdoor temperature that will turn off the hydronic heating module
and operate the appliance only as a water heater for the warmer weather. To adjust this value, press
ENTER
and the factory default of 68°F starts to blink. Use
▲
and
▼
to adjust this value to your system
needs. To store the new value press
ENTER
.
13. Next, press
once to scroll to Function 5 - “MIN OUTDOOR TEMP”. This function is the first step to
setting the outdoor reset curve. Enter your system’s minimum outdoor temperature value. To adjust the
value, press
ENTER
and the factory default of 5 °F starts to blink. Use
▲
and
▼
to adjust to your
designed temperature. To store the new value press
ENTER
.
Summary of Contents for Versa Hydro PHE130-119
Page 23: ...23 Figure 5 Figure 6 ...
Page 24: ...24 Figure 7 ...
Page 25: ...25 F HYDRONIC PIPING Figure 8 ...
Page 26: ...26 Figure 9 ...
Page 27: ...27 Figure 10 ...
Page 28: ...28 Figure 11 ...
Page 29: ...29 Figure 12 ...
Page 32: ...32 F INTERNAL WIRING Figure 14 Internal connection diagram ...
Page 38: ...38 Figure 17 ...
Page 48: ...48 Figure 25 ...
Page 76: ...76 Figure 29 ...
Page 77: ...77 Figure 30 ...
Page 78: ...78 Figure 31 LP 314 G ...
Page 79: ...79 Figure 32 ...
Page 81: ...81 ...
Page 82: ...82 ...
Page 83: ...83 MAINTENANCE NOTES ...