16
Values mentioned above are measured when the environment temperature is 25°C.
The maximum allowed continuous current for the opto-isolated output port is 50 mA. Any current
exceeds the extreme value might result in port damage.
IO Smoothing
3.8
LineDebouncerTimeAbs
: IO port smoothing. Only available under input mode, it filters the level
signals of the cable connected to the corresponding port based on the defined value. If the signal
value is lower than the defined value, it will be filtered.
For example, set the
LineDebouncerTimeAbs
value to 1500 us.
Configure filter value
Figure 3-23
Before smoothing
Figure 3-24
After smoothing
Figure 3-25
When the
LineDebouncerTimeAbs
value is higher than that of the high-low level, as the above
example, the smoothing level is higher than 5000 us, the camera has no stream. Do not set the
LineDebouncerTimeAbs
value higher than that of the high-low level.
Black Level
3.9
The camera supports black level which can adjust the gray level deviation of the output data and
decides the average gray level when the sensor is not photosensitive. Different ADC bit depth
modes corresponds to different black level parameter range of the camera.
Configure black level.
Select
Once
or
Continuous
under
Analog
Control
>
Black
Level
Enable
.
Step 1
Enter the value in
Black
Level
as needed.
Step 2