background image

 

PRODUCTS INTRODUCTION 

---------P5-------- 

 

1.5 Four-channel LCD display instructions (HE704

HE804) 

1

2

3

4

5

6

7

8

10

11

12

13

14

9

16

17

18

15

 

 

 This symbol showing being the setup mode   

  This symbol shows being the 

manual-recoding data checking status   

  This symbol shows being the maximum or 

minimum data checking status   

 Symbol for clock  

  Sensor type symbol display area 

  Year/month-date/time alternate display 

area  

  T1,T2,T3,T4 for channel 1, channel 2, 

channel 3 and channel 4 respectively   

  This symbol shows that instrument is 

being connected with PC 

  Data symbol for channel 1, channel 2, 

channel 3 and channel 4   

  This symbol shows setting limits are 

being exceeded   

 This symbol shows that manual-recording 

data can be deleted   

  Temperature unit for channel 1, channel 

2, channel 3 and channel 4 

  This symbol shows that instrument is being 

connected with PC   

  This symbol shows being the maximum 

and minimum data checking status 

  Battery status indication   

  This symbol shows being the holding 

fixed measuring data status 

  This symbol shows instrument is being the 

logging status 

 

  Capacity for auto-recording or 

manual-recording data 

 

Summary of Contents for HE70X Series

Page 1: ...Operation Manual for HE70X 80X Series Multi channel thermocouple thermometer Huato Electronic Shenzhen Co LTD...

Page 2: ...E802 4 1 5 FOUR CHANNEL LCD DISPLAY INSTRUCTIONS HE704 HE804 5 1 6 INSTRUCTIONS FOR BUTTONS FUNCTION 6 CHAPTER 2 INSTRUCTIONS FOR SOFTWARE OPERATION 7 2 1 QUICK START 7 2 2 CONNECTING THE THERMOMETER...

Page 3: ...uato specialized Tespro software is easy to operate and quite convenient widely applied in industrial production fields food processing industry pharmaceutical industry and research testing fields as...

Page 4: ...0 88 HE802 2 0 1 0 5 36000 88 HE804 4 0 1 0 5 36000 88 Notice The accuracy on the above table is only the accuracy for thermometer itself The precision in the practical applications has relation with...

Page 5: ...nd minimum data checking status This symbol shows instruments being the connection status with PC This symbol shows being the holding fixed measuring data status Maximum and minimum data checking butt...

Page 6: ...ymbol shows that instrument is being connected with PC This symbol shows that the setting limits for channel 1 or channel 2 are being exceeded Display area for channel 1 and channel 2 This symbol show...

Page 7: ...el 4 respectively This symbol shows that instrument is being connected with PC Data symbol for channel 1 channel 2 channel 3 and channel 4 This symbol shows setting limits are being exceeded This symb...

Page 8: ...show DIS in the LCD corner means CAN T switch show En and press OK to delete auto recording data 4 SETUP TYPE lighting from K moving on one by one OK key to confirm the sensor type 1 Setup switch but...

Page 9: ...sample and record and the LCD display is off Tespro cannot connect to the logger also 2 2 Connecting the Thermometer Data Logger to PC To connect the thermometer data logger to the computer follow th...

Page 10: ...ame Gives a name to the logger z SN Every logger has a SN with 10 characters The length must be 10 z Sampling Interval The interval of sampling z LOG Intervals s The interval of recording z Logs Count...

Page 11: ...ows will be displayed The graph display will be blank if there are not any logs Note Push left mouse button down and then move to select a rectangle area when the left mouse button is up the graph wil...

Page 12: ...Click button on the toolbar and then the data listing window is shown below The data pane lists the data samples collected by the logging device The column width of each column is adjustable by using...

Page 13: ...rt sample data to an Excel file z Export sample data to a text file z Export graph to a BMP file 2 8 File List The file list pane lists all the files in the directory Logfiles which is located in the...