background image

 

                                                     

1

                                                                                                                                 

2

                                                                                                                               

3

 

 

1288H V5 Server Quick Start Guide 

Document Issue: 07 (2018-10-30)          BOM: 31508821 (2/3) 

 

Huawei Technologies Co., Ltd.                                                                         

 

 

  

 

Copyright © Huawei Technologies Co., Ltd. 2018 All rights reserved. 

No part of this document may be reproduced or transmitted in any form or by any means without prior written consent of Huawei 
Technologies Co., Ltd. 

and other Huawei trademarks are trademarks of Huawei Technologies Co., Ltd. 

All other trademarks and trade names mentioned in this document are the property of their respective holders. 

The information in this document is subject to change without notice. Every effort has been made in the preparation of this 
document to ensure accuracy of the contents, but all statements, information, and recommendations in this document do not 
constitute a warranty of any kind, e

x

press or implied. 

1.

 

Specifications 

The Huawei FusionServer 1288H V5 server (1288H V5) is designed for high-performance 
computing, database, web server, virtualization, basic enterprise, and telecom service 
applications.   

Technical Specifications 

For details, see the

 1288H V5 Server V100R005 User Guide

Dimensions 

(H x W x D) 

 

Chassis with 3.5-inch hard drives:   
43 mm x 436 mm x 748 mm (1.69 in. x 17.17 in. x 29.45 in.) 

 

Chassis with 2.5-inch hard drives:   
43 mm x 436 mm x 708 mm (1.69 in. x 17.17 in. x 27.87 in.) 

Temperature 

 

Operating range: 5°C to 45°C (41°F to 113°F)   
(ASHRAE Classes A3 and A4 compliant) 

 

Storage range: –40°C to +65°C (–40º

F to + 149º

F) 

 

Maximum change rate: 20°C/h (36°F/h) 

Relative humidity 
(RH, non-condensing) 

 

Operating range: 8% to 90%   

 

Storage range: 5% to 95% 

 

Maximum change rate: 20%/h 

Maximum altitude 

 

≤ 3050 m (10006.44 ft). According to the ASHRAE standards of 
2015, for altitudes above 950 m (3116.79 ft), the highest 
operating temperature decreases by 1°C (1.8°F) for every 
increase of: 

o

 

300 m (984.24 ft) in altitude when the server configuration 
complies with Class A2 standards. 

o

 

175 m (575.14 ft) in altitude when the server configuration 
complies with Class A3 standards. 

o

 

125 m (410.10 ft) in altitude when the

 server 

configuration 

complies with Class A4 standards. 

 

HDDs cannot be used at an altitude of over 3000 m (9842.5 ft). 

2.

 

Front and Rear Panels 

 

Built-in DVD drive (optional) 

Label plate with an SN label 

Fault diagnosis LED 

Health indicator 

Network port connection status indicator 

NMI button 

Power button/indicator 

UID button/indicator 

USB 2.0 port 

10 

USB 3.0 port 

11 

VGA port 

12 

Hard drive fault indicator 

13 

Hard drive activity indicator 

14 

Hard drive 

 

PCIe slot 1 

Data transmission status indicator 

Connection status indicator 

Data transmission status indicator 

Connection status indicator 

PCIe slot 2 

PCIe slot 3 

Power supply module (PSU) 1 

PSU indicator 

10 

PSU latch 

11 

PSU 2 

12 

PSU sockets 

13 

Flexible NIC (optional) 

14 

USB 3.0 ports 

15 

UID indicator 

16 

Serial port 

17 

Management network port 

18 

GE electrical ports 

19 

VGA port 

20 

10GE electrical port 

21 

Connection status indicator/Data 
transmission status indicator 

22 

Transmission rate indicator 

23 

10GE optical port 

24 

Transmission rate indicator 

25 

Connection status indicator/Data 
transmission status indicator 

 

3.

 

Indicators and Buttons 

Indicators and buttons on the front panel 

No. 

Indicator 

State Description 

Remarks 

Fault diagnosis 
LED 

 

---: The server is operating normally. 

 

Error code: A server component is faulty. 

For details about 
error codes and 
alarm handling, 
see the 

Huawei 

Rack Server iBMC 
Alarm Handling

Health indicator 

 

Steady green: The server is operating 
properly.   

 

Blinking red at 1 Hz: A major alarm has 
been generated on the server.   

 

Blinking red at 5 Hz: A critical alarm has 
been generated on the server. 

Network port 
link indicator 

There are two 10GE and two GE ports. 

 

Steady green: The network port is properly 
connected.   

 

Off: The network port is not in use or has 
failed.   

When a network 
port is faulty, 
contact Huawei 
technical support 
to replace the 
mainboard. 

NMI button 

A non-maskable interrupt (NMI) is generally 
triggered to stop the OS for debugging. To 
trigger an NMI, you can press this button or 

None 

No. 

Indicator 

State Description 

Remarks 

click the button on the iBMC WebUI. 

NOTICE 

 

Do not press this button when the server is 
operating  properly.  An  NMI  does  not 
gracefully  shut  down  the  OS  and  causes 
service interruption and data loss. 

 

Before pressing this button, ensure that the 
OS  has  the  NMI  processing  program. 
Otherwise, the OS may crash. 

Power 
button/indicator 

Power indicator 

 

Off: The server is not connected to a power 
source.   

 

Blinking yellow: The iBMC is starting.   

 

Steady yellow: The server is ready to power 
on.   

 

Steady green: The server is properly 
powered on. 

Power button 

 

When the server is powered on, you can 
press this button to shut down the OS. 

 

When the server is powered on, holding 
down this button for 6 seconds will forcibly 
power off the server. 

 

When the server is ready to be powered on, 
you can press this button to start the server. 

None 

UID 
button/indicator 

UID indicator 

 

Steady or blinking blue: The server is being 
located. 

 

Off: The server is not being located. 

UID button 

 

You can press this button to turn on or off 
the UID indicator. 

 

Pressing and holding down this button for 4 
to 6 seconds will reset the iBMC. 

None 

 

Indicators and buttons on the rear panel 

No. 

Indicator 

State Description 

Remarks 

PSU indicator 

 

Steady green: The power input 
and output are normal. 

 

Blinking green at 1 Hz:   

 

The input is normal, the 
server is standby, and the 
PSU is in MV6 mode. (The 
output voltage is 6.7 V.) 

 

The input is overvoltage or 
undervoltage.   

 

The PSU is in deep 
hibernation mode. 

 

Blinking green at 4 Hz: An 
online firmware upgrade is 
being performed. 

 

Steady orange: The input is 
normal, but no power output is 
supplied due to overheat 
protection, overcurrent 
protection, short circuit 
protection, output overvoltage 
protection, or some component 
failures. 

Replace the 
PSU if the 
indicator is in 
any of the 
following 
states:   

 

Blinking 
green at 1 
Hz after 
the server 
is 
normally 
powered 
on. 

 

Steady 
orange 

Reviews: