No.
Cable or Device Description
2
Network cable
l
The service network cable and PoE input cable cannot
be connected to the console port. Otherwise, the AP
may be damaged when using PoE power supply.
l
If the AP needs to connect to the Ethernet, ensure that
the Ethernet cable is working properly. If the Ethernet
cable is not working properly, for example, RJ45
connectors are short-circuited, the AP may fail to be
powered on or fail to work. Before connecting an
Ethernet cable to the AP, use the cable test tool to
check whether the cable is qualified. If the cable is
unqualified, replace it.
NOTICE
l
Do not insert a PoE input cable into the GE1/PoE_OUT port.
l
CAT5e cables or higher must be used.
l
The length of a cable in the GE0/PoE_IN interface cannot
exceed 100 m.
l
The length of a cable cannot exceed 40 m when the GE1/
PoE_OUT port has PoE output and cannot exceed 100 m
when there is no PoE output.
l
The GE1/PoE_OUT port of an AP can provide power output
only works in 802.3at PoE mode. The output power varies at
different connection status:
l
The maximum output power is 7 W when no IoT card is
connected to the AP and the USB port is not used.
l
The maximum output power is 5.5 W when only one IoT
card is connected to the AP and the USB port is not used.
l
The PoE_OUT function is automatically disabled when
two or more IoT cards are connected to the AP or the
USB port is used.
3
DC power adapter
When the AP uses the DC power supply, use a power
adapter for power supply; otherwise, the AP may be
damaged.
4
RF cable
Connects to an IoT card or an antenna.
NOTE
The AP is powered by either the DC power supply or PoE power supply that backs up each other.
When installing a cable, you must make a drip loop to prevent water from flowing into
devices along the cable. For the method of making the drip loop, see
.
Pay attention to the following points when bundling the cables:
l
Different types of cables must be separately routed with the minimum spacing of 30 mm
and cannot be entangled or crossed. Cables should be parallel or separated using
dedicated separators.
l
Bundled cables are closely arranged, straight, tidy, and undamaged.
AP4050DN-E
Hardware Installation and Maintenance Guide
2 AP Installation
Issue 05 (2018-02-02)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
22