Figure 5-8
Tightening the nut
Step 8
Use a multimeter to check the connectivity of the 2-pin round connector's cable components,
as shown in
.
Figure 5-9
Checking connectivity
The connectivity meets standards if the following conditions are met:
l
Positive and negative holes of the connector are not short-circuited.
l
The metal enclosure and connector's holes are not short-circuited.
l
The cable shield layer is properly connected to the metal enclosure.
l
Core wires are properly connected to the connector's holes.
Step 9
If devices are installed outdoor, wrap three layers of PVC insulation tape around the
connector for protection, as shown in
.
NOTICE
Ensure that proper quantity of the PVC insulation tape is used for wrapping the connector,
facilitating the connector uninstallation in later maintenance.
AP4050DN-E
Hardware Installation and Maintenance Guide
5 Appendix
Issue 05 (2018-02-02)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
40