l
M4: 1.4 N•m
l
M6: 4.8 N•m
l
M8: 12 N•m
Ground cable deployment requirements are as follows:
l
The ground cables must be connected to a group of ground bars.
l
The bend radius of the ground cables must be larger than or equal to five times the cable
diameter.
l
The ground cables must be buried underground or routed indoors and cannot be led into
the equipment room aerially.
l
Both ends of the external conductor of the coaxial cable and those of the shield layer of
the shielded cable should have good electric contact with the metal shell of the
equipment they connect to.
l
Ground cables must be separated from signal cables to reduce interference between
them.
l
Do not add any switch or fuse on the ground cable.
l
Do not use another device for an electrical connection with the ground cable.
l
All metal components in the shell must be securely connected to the ground terminal.
2.7 Connecting the Security Lock
There is a security slot on the device. You can lock the device to an immovable object to
prevent theft. The detailed procedures are as follows:
1.
Fasten the cable of the security lock to an immovable object around.
2.
Insert the security lock into the security slot and lock it.
Lock hole
Security lock
NOTE
You need to purchase the security lock separately.