AP7052DN&AP7152DN
Hardware Installation and Maintenance Guide
5 Appendix
Issue 01 (2017-12-29)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
155
Com
pone
nt
No.
Applic
able
Scope
Check Item
7
Outdoor
antenna
The pole used in antenna mounting should meet the
following requirements:
Pole height: ≥ 2000 mm
Bottom pole diameter: ≥ 220 mm
Top pole diameter: ≥ 120 mm
Pole thickness: ≥ 6 mm
Depth of foundation: ≥ 1500 mm
The pole deployed outdoors must be reinforced with hot-dip
zinc to prevent water corrosion and rust.
8
Outdoor
antenna
It is recommended that at most three APs or antennas be
mounted to the same pole. The APs or antennas mounted to
the same pole should meet the following requirements:
The vertical distance should be at least 3.5 m between
adjacent 2.4G antennas and 2 m between adjacent 5G
antennas.
There should be at least 1 m vertical distance between
antennas that work on the same frequency band and
belong to different APs.
9
Outdoor
antenna
When outdoor APs use single-polarized antennas, the
horizontal distance between 2.4G antennas should be at least
1 m and that between 5G antennas should be at least 0.5 m.
10
Outdoor
antenna
If multiple APs are mounted to different poles, the APs
should provide signal coverage in the same direction or in
back-to-back mode to ensure that main lobe of antennas on
different APs do not face each other.
Recommended AP distance:
≥ 44 m (APs provide signal coverage in the same direction)
≥ 6 m (APs provide distance in back-to-back mode)
Power
and
groun
d
cables
1
General
The female connectors of power cables connecting to the
device are fixed using a locking latch.
2
General
The power cables and ground cables are correctly connected.
3
General
The power cables and ground cables are complete and not
spliced.
4
General
The excess of power cables or ground cables are trimmed off
without any coils. The power cables connecting the delivered
surge protection boxes and devices cannot be cut. These
power cables can be coiled.
5
General
Power cables and ground cable are separated from the signal
cables.
6
General
Power cables and ground cables are routed straightly and
properly bundled, with sufficient slack at the bend part. If the