AP7052DN&AP7152DN
Hardware Installation and Maintenance Guide
5 Appendix
Issue 01 (2017-12-29)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
85
Connect multimeter probes to two ends of each wire in a network cable and check the
resistance value on the multimeter.
Connect a network cable to an AP. Use a multimeter to test the resistance between pins 1
and 2 (or between pins 3 and 6, 4 and 5, or 7 and 8) on the other end of the cable. The
cable's DC resistance approximately equals a half of the displayed value.
Table 5-13
PoE standard requirements for network cable quality
Standard
Total
Resistance of
a Network
Cable
802.3af
≤ 20 ohms
802.3at
Maximum PD power consumption <
12.95 W
≤ 20 ohms
Maximum PD power consumption <
25.5 W
≤ 12.5 ohms
If an AP is connected to a switch or AC (excluding ACU2), you can run the
virtual-cable-test
command on the switch or AC to check network cable connectivity. For details, see the
virtual-cable-test
command in the command reference.
5.1.4 Assembling Feeders
5.1.4.1 Assembling the Straight Male Coaxial N Connector and the 1/2''
Feeder
Context
Figure 5-89 shows the components of an N coaxial connector and a 1/2" feeder cable.
Figure 5-89
Components of an N coaxial connector and a 1/2" feeder cable
A. Body of
connector
B. Back shell of
connector
C. O-ring seal
D. Heat-shrink tubing
E. Cable jacket
F. Outer conductor of
feeder cable
G. Inner conductor of
feeder cable
H. Insulation layer of
feeder cable