Table 3-1
Board configuration of the BBU3900
Board
Mandatory/
Optional
Maximum
Configured
Number
Installation
Slot
Requirements
WMPT
Mandatory
2
slot 6 or 7
The WMPT is
preferentially
configured in
Slot 7.
WBBP
Mandatory
4
slots 0 to 3
The WBBP is
installed in slot
3 by default.
l
If extension
CPRI ports
are required,
the board is
installed in
slot 2.
l
If extension
CPRI ports
are not
required, the
priority of
the
installation
position of
the board is
from slot 0 to
slot 1, and
then to slot 2.
FAN
Mandatory
1
slot 16
The FAN is
preferentially
configured in
the slot 16.
UPEU
Mandatory
2
slot 18 or slot 19 The UPEU is
preferentially
configured in
slot 19.
UEIU
Optional
1
slot 18
The UEIU is
configured in
slot 18.