Table 7-5
Power cables to be installed onsite (in a DC cabinet)
Cable
One End
The Other End
Connector
Installation
Position
Connector
Installation
Position
OT terminal
RTN(+) and
NEG(-)
terminals on the
INTPUT: -48 V
side of the
PDU10D-01
Depending on
the external
power
equipment
External power
equipment
EPC4 or
EPC6
connector
LOAD6 on the
PDU10D-01
3V3 connector
-48V on the
UPEU
EPC4 or
EPC6
connector
LOAD0 on the
PDU10D-01
Depending on
the RRU type
NEG(-) and
RTN(+)
terminals on the
RRU
Transmission Cables
lists the transmission cables that have been installed before delivery.
the transmission cables and CPRI fiber optic cables that need to be installed onsite.
Table 7-6
Transmission cables installed before delivery
Cable
One End
The Other End
Connector
Installation
Position
Connector
Installation
Position
E1/T1 Surge
Protection
Transfer Cable
DB25
connector
INSIDE port on
the UELP in the
BBU
DB26 connector E1/T1 port on
the GTMU,
WMPT, or
UTRP in the
BBU
FE Surge
Protection
Transfer Cable
RJ45
connector
l
FE0 port on
the GTMU
or WMPT in
the BBU
l
FE0 or FE1
port on the
LMPT in the
BBU
RJ45 connector
FE0 port in the
INSIDE part on
the UFLP in the
BBU
BTS3900C (Ver.C)
Hardware Description
7 BTS3900C Cables
Issue 03 (2013-05-27)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
124