Figure 3-4
Slots in the BBU3900
BBU3900 Working in GO Mode
describes the principles for configuring the boards in the BBU3900 working in GO
mode.
Table 3-1
Principles for configuring the boards in the BBU3900 working in GO mode
Board
Optional/
Mandatory
Maximum
Quantity
Installation
Slot
Remarks
GTMU
Mandatory
1
Slots 5 and 6
It is configured
only in slot 6
(with slots 5 and
6 occupied).
FAN
Mandatory
1
Slot 16
It is configured
only in slot 16.
UPEU
Mandatory
2
Slot 18 or 19
A single UPEU
is preferentially
configured in
slot 19.
USCU
Optional
1
Slot 0 or 1
It is
preferentially
configured in
slot 1.
The 1 U GPS/
GLONASS
receiver is
configured in
slot 1 (with slots
0 and 1
occupied).
UTRP
Optional
1
Slot 0 or 4
It is
preferentially
configured in
slot 4.
UEIU
Optional
1
Slot 18
-
UBRI
Optional
1
Slot 2
-
BTS3900C (Ver.C)
Hardware Description
3 BTS3900C Modules
Issue 03 (2013-05-27)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
15