Figure 2-9
Rear view of the AC rectifier module
shows the description of indicators on the panel of the AC rectifier module.
Table 2-7
Indicator description
Indicator
Color
Normal
Abnormal
Cause
Power running
indicator
Green
On
Off
Power failure
(no AC input,
over-voltage
AC input, or
under-voltage
AC input) and
no output by the
power module
Protection
indicator
Yellow
Off
On
Temperature
alarm (When the
ambient
temperature
exceeds 65°C,
the device is
powered off.)
Dormant (When
the device is in
dormant state,
the protection
indicator of the
module is on,
but the module
does not report
alarms.)
HUAWEI Eudemon8000E Firewall
Hardware Description
2 E8000E-X16 Chassis Overview
Issue 01 (2012-11-07)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
15