Table 2-13
Buttons and indicators on the panel
LED
Description
RUN
(green)
Before the registration of the SFU: If the indicator blinks twice every second (2
Hz), the system is in the alarm state.
After the registration of the SFU: If the indicator blinks once every two seconds
(0.5 Hz), the system is running normally.
ACT
(green)
If the indicator is on, it indicates that the SFU is working normally; if the green
indicator is off, it indicates that the SFU is faulty.
OFL (red) When the SFU is working normally, the OFL indicator is off. After the OFL
button is pressed to power off the SFU, the OFL indicator is on.
NOTE
The SFUI-40-B can be used only on the E8000E-X16.
Technical Specifications
shows the technical specifications of the SFUI-40-B.
Table 2-14
Technical specifications of the SFUI-40-B
Item
Description
Silkscreen of the board name
SFUI-40-B
Dimensions (W x D x H)
410 mm x 553.5 mm x 40.5 mm
Power consumption (typical value)
50 W
Board weight
3.5 kg
2.9 Control Plane
This chapter describes the control plane of the E8000E-X16.
2.9.1 Introduction to the Control Plane
This section describes the functions of the control plane.
The control plane on the E8000E-X16 is responsible for system control and management,
including route calculation, device management and maintenance, and device monitoring.
E8000E-X16 uses the MPUB and CMU to implement the system control and management
functions of the control plane. The functions include route calculation and device management,
maintenance, and monitoring. The functions are described as follows: