EDGE U0-6 Simplified Maintenance Manual
11 Quality Inspection Procedure and Methods
Issue 1.0 (2013-01-12)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
66
Item
Description
Reference Value
Test the standby current.
< 10 mA
Charging test Connect the phone to a power adapter, charge the
phone for 15 minutes, and check the power remaining
increasement of the battery. (Ensure that the power
remaining of the battery is lower than 50% before
charging it.)
> 3%
MMI test
Test the functions of the peripheral parts, such as the
audio and display components.
All pass
MT
Test the phone's reception on 2G and 3G networks.
All pass
11.2 Inspection Tools
Table 11-2
Inspection tools
Tool
Function
Picture
Multimeter
Used for the battery test
Tests the battery voltage.
DC power supply
Used for the current test
Tests the phone current.
Connection cables
Used for the current test
Connect the DC power supply
to the phone.
microSIM card
Used for the MMI test
Tests the SIM card function
of the phone.