l
Keep your password secure.
Procedure
Step 1
Choose
System
>
Password Change
. The
Password Change
page is displayed.
Step 2
Change the password in
Password Change
.
NOTICE
The password of the
acs
user must be changed on both the eOMC910 and the Web management
interface.
Step 3
Click
Submit
.
----End
7.7.6 Password Complexity
This section describes how to query and set the password complexity on the
Password
Complexity
interface.
Context
You can query and set the password complexity. After the settings take effect, the new password
must meet the complexity requirements when you change the password.
The complexity requirements are as follows:
l
The password must contain 8 to 32 characters.
l
The password must contain at least two character types and must not contain three or more
than three consecutively same characters.
The character types include:
–
Lowercase letters
–
Uppercase letters
–
Digits
–
Special characters `~!@#$%^&*()-_=+\|[{}];:'",<.>/?, and space
l
The password must not contain the account name or its reversion.
For example, if the user name is
TD4GCPE
, the password must not be
TD4GCPE
or
EPCG4DT
.
Procedure
Step 1
Choose
System
>
Password Complexity
. The
Password Complexity
interface is displayed.
Step 2
Set the password complexity rules in
Config Password Complexity
.
Step 3
Click
Submit
.
----End
EG860
User Guide
7 Reference
Issue 02 (2015-04-10)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
100