7.7.7 Password security Settings
This section describes how to set password security policies on the
Password security
Settings
interface.
Procedure
Step 1
Choose
System
>
Password security Settings
. The
Password security Settings
interface is
displayed.
Step 2
Set password security policies on the
Password security Settings
interface.
The related parameters are as follows:
l
Login Fail count
: indicates the maximum login attempts to the WebUI. Value range:
1-10
.
l
Login Lock time
: indicates the account lockout duration if the number of login attempts
exceeds the specified value. Value range:
60-3600s
.
l
Change password count
: indicates the maximum password change attempts. If the number
of change attempts exceeds the specified value, the user must log in to the system again.
Value range:
1-10
.
Step 3
Click
Submit
.
----End
7.7.8 Date & Time
Date and time information is lost each time a router is powered off. It is recommended to enable
the synchronization with network time function.
Procedure
Step 1
Choose
System
>
Date & Time
. The
Date & Time
page is displayed.
Step 2
Click
Manually set with local time
or
Synchronize with network time
to set time and date as
required.
For detailed information about the parameters, see the online help on the right of the Web
management interface.
Step 3
Click
Submit
.
----End
7.7.9 Diagnosis
Ping and Traceroute helps you quickly detect network connection status and the system check
allows one-click self-check. Main/Neighbor Cell displays current main/neighbor cell
information in real time. Chip temperature shows the current temperature of device internal
environment. Tcpdump provides packet capture at ports. Tmsi provides Tmsi information query.
Up/Down Throughup displays current throughput in real time. Work Frequency displays the
current working frequency. Packet Stat displays the number of packets received/transmitted at
a port. WAN ICMP controls whether to discard the ICMP packets received at the WAN port.
EG860
User Guide
7 Reference
Issue 02 (2015-04-10)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
101