Related Information
None
8.3 ALM 50003-RadioSignal Weak
This alarm is reported when the signals received by an EG860 are weak.
Attribute
Alarm ID
Alarm Severity
Alarm Type
50003
Major
Fault
Parameters
None
Impact on the System
Alarm Severity
Alarm Impact
Major
Air interface signals received by the EG860
are weak and services may be affected.
System Actions
None
Possible Causes
Cause Category
Possible Cause
Environment
The
feeder connection of the EG860 is
faulty.
Configuration
The signals of the cell in which the EG860
resides are weak.
Procedure
l
Check whether the
feeder connection of the EG860 is normal.
l
Check the signal strength in the cell in which the EG860 resides. To perform this check,
log in to the
and choose
System
>
Diagnosis
.
EG860
User Guide
8 Alarm Reference
Issue 02 (2015-04-10)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
111