Figure 5-35 Setting the external IP address of the OMU
Step 2 Enable camera NTP synchronization.
The camera NTP synchronization function for the server is disabled by default. The
camera NTP synchronization function needs to be enabled for the server that
connects to the camera. After the camera NTP synchronization function is enabled,
cameras will automatically time-synchronize from their access servers.
1. Log in to the OMU portal of the VCN as user admin.
2. Choose Maintenance > Unified Configuration.
3. Select the server that the camera needs to access, set Module name to SCU
and Parameter type to System property, and click Search.
Figure 5-36 Configuring camera NTP synchronization
4. In the search results, click Edit in the row where Parameter Name is NTPIPC
and set Value to 1.
5. Click Save. After the camera NTP synchronization function is enabled, the
camera, after being connected to the server, will automatically synchronize
time with the server.
----End
Follow-up Procedure
●
(Optional) Set up a VCN stack. For details, log in to the https://
e.huawei.com/, search for the VCN product documentation, open the
documentation, and see the section (Optional) Deploying IVS in Stack
Mode.
●
(Optional) Create a VCN cluster. For details, log in to the https://
e.huawei.com/, search for the VCN product documentation, open the
documentation, and see the section (Optional) Deploying MPUs in Cluster
Mode.
FusionModule500 Smart Mini Data Center
User Manual
5 Power-On Commissioning
Issue 02 (2020-12-25)
Copyright © Huawei Technologies Co., Ltd.
201