Figure 4-25
Drilling holes and installing expansion bolts
(1) M6×60
expansion bolt
(2) Nut
(3) Spring washer
(4) Flat washer
(5) Extension tub
1.
Use a hammer drill with bit 8 to drill holes with a diameter of 8 mm and a depth of 45 mm
to 50 mm at the marked anchor points. All the holes have the same depth.
2.
Use a vacuum cleaner to clear the dust inside and around each hole. If the distance between
two holes is incorrect, mark and drill holes again.
3.
Partially tighten an expansion bolt and place it vertically into each hole.
4.
Use a rubber mallet to hit the expansion bolt until the entire expansion sleeve is in the hole.
5.
Remove the M6×60 bolt, nut, spring washer, and flat washer from each expansion bolt in
sequence.
NOTICE
After removing an expansion bolt, ensure that the top of the expansion sleeve is level with
the wall. If it is not level, the RHUB cannot be installed on the concrete floor evenly and
securely.
Step 4
Align the mounting holes with the four M6×60 expansion bolts. Install spring washer 6 and flat
washer 6 in sequence on each M6×60 expansion bolt, insert the bolts to each expansion tub, and
then use a torque wrench or socket wrench to tighten the four M6×60 bolts with a torque of 5
N•m to secure the RHUB to the wall, as shown in
LampSite
Installation Guide
4 Installing an RHUB
Issue 02 (2014-05-27)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
27