HUAWEI MU609 HSPA LGA Module
Application Guide
Sleeping and Waking Up Application Scenarios
Issue 02 (2013-09-18)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
79
10.2 Sequence Diagram
Figure 10-1
WAKE#/WAKEUP_OUT (when a NPN triode is externally connected to the
WAKEUP_OUT pin) output sequence
Figure 10-2
WAKEUP_IN input sequence
WAKEUP_IN:
Module status:
High level
Low level
Low level
Sleep State
Sleep State
Operating state
Other modules that have the vote right
approve of the module’s sleep
About the vote, see section 10.4.1 .