Prerequisites
The following tools and materials have been ready:
l
Optical fibers
l
Fiber bundling tape
l
8 Gbit/s optical transceiver
l
Diagonal pliers
Context
CNENs and SUCs can be networked directly or through switches. As shown in
, a
direct connection network contains the following parts:
l
2 to 4 CNENs
l
1 to 4 SUCs
l
No support for online expansion of CNENs and SUCs
Figure 5-24
Directly connecting two CNENs to one SUC
NOTE
You can add a Fibre Channel host bus adapter (HBA) to the CNEN for providing more Fibre Channel ports
to connect directly to SUCs. For details on how to add Fibre Channel ports and obtain information about
direct connection, see
10.1 Directly Connecting CNENs to SUCs (with the S2600T Storage System as
, a switch connection network contains the following parts:
l
2 to 4 CNENs
l
1 to 18 SUCs
l
Support for online expansion of CNENs and SUCs
OceanStor N8500 Clustered NAS Storage System
Installation Guide (for T Series V100R005)
5 N8500 Installation (with the S2600T Storage System as the
Storage Unit)
Issue 02 (2015-09-22)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
68