Figure 5-25
Connecting CNENs to SUCs through Fibre Channel switches
Procedure
Step 1
Determine a network connection mode.
l
Direct connection: applicable to a configuration of 2 to 4 CNENs and 1 to 4 SUCs
l
Switch connection: applicable to a configuration of 2 to 4 CNENs and 1 to 18 SUCs
Step 2
Set up a network containing the cluster NAS engine and storage control unit.
l
Direct connection
Connect 4 or 8 Fibre Channel ports on each CNEN respectively to two 8 Gbit/s Fibre Channel
port on SUC's controllers A and B.
l
Switch connection
OceanStor N8500 Clustered NAS Storage System
Installation Guide (for T Series V100R005)
5 N8500 Installation (with the S2600T Storage System as the
Storage Unit)