Figure 5-26
Connecting one SUD to one SUC
NOTE
The numbers following SUDs, as shown in
, are enclosure IDs
of SUDs.
The enclosure ID of the first SUD that is positively connected by an SUC's controller A is automatically
identified as 1.
To connect two SUDs to one SUC, attach ports EXP 0 on the SUC's controllers A and B to ports
PRI on one SUD's disk modules A and B. One expansion loop is generated. Then attach ports
EXP 1 on the SUC's controllers A and B to ports PRI on the other SUD's disk modules A and
B. The other expansion loop is generated, as shown in
OceanStor N8500 Clustered NAS Storage System
Installation Guide (for T Series V100R005)
5 N8500 Installation (with the S2600T Storage System as the
Storage Unit)
Issue 02 (2015-09-22)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
71