OptiX OSN 8800/6800/3800
Hardware Description
4 OptiX OSN 8800 Subrack
Issue 01 (2016-03-10)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
88
Unit Name
a
Typical
Power
Consumpt
ion
a
Maximu
m Power
Consump
tion
a
Remarks
ck
2
EFI, 2 x SCC, and fan tray assembly
OTM
subra
ck
Subrack
1
709
877
4 x TN17TX, 2 x PIU, 1 x EFI, 2 x SCC,
and fan tray assembly
Subrack
2
649
809
4 x TN17LSC, 2 x PIU, 1 x EFI, 2 x SCC,
and fan tray assembly
Subrack
3
170
354
1 x M40V, 1 x D40, 1 x OAU101, 1 x
OBU103, 1 x FIU, 1 x SC1, 2 x PIU, 1 x
EFI, 2 x SCC, and fan tray assembly
OLA subrack
145
315
2 x OAU101, 2 x FIU, 1 x SC2, 2 x PIU,
1 x EFI, 2 x SCC, fan tray assembly
ROA
DM
subra
ck (4
x
dime
nsion
s)
b
Subrack
175
351
1 x WSMD4, 1 x DAS1, 1 x M40, 1 x
D40, 2 x PIU, 1 x EFI, and fan tray
assembly
OTM cabinet
1528
2040
OTM subrack1, OTM subrack2, and
OTM subrack3
a: Indicates that the power consumption of the subrack and cabinet is the value in a certain
configuration. The value is for reference only. The actual power consumption of the chassis
and cabinet is calculation based on the power consumption of each module. The maximum
power consumption is the power consumed by the board when it works normally under the
highest ambient temperature.
b: At the ROADM site, it is recommended to deploy one subrack per direction. This table
assumes that the four directions are configured identically and provides only the reference
configurations for one direction.
4.5.6 AC Power Consumption
This section describes the maximum and typical subrack AC power consumption
specifications.
describes the AC power consumption of a universal platform subrack.
For transport equipment, the heat consumption and power consumption are similar and can be
considered the same. Heat consumption is expressed in BTU/h and power consumption is expressed in
W. The conversion between the two units is as follows: 1 BTU/h = 0.2931 W.
Typical configuration power consumption indicates the average power consumption of the equipment
with the typical configuration and the equipment runs at the room temperature. Maximum power
consumption indicates the possible maximum power consumption when the equipment runs in an
environment with extreme conditions.