Installation Manual 
Quidway Eudemon 200 Firewall 

Chapter 5  Hardware MaintenanceHardware

 Maintenance

 

5-4

 

5.4  RPU Removal and Installation

 

5.4.1  Remove an RPU

 

Step 1: 

Power off the switch. (If there are two power modules installed, turn both of 

them off).

 

Step 2:

 Loosen the captive screws at both sides of the RPU.

 

Step 3:

 Pull the handles at both sides of the RPU outward and gently pull the RPU out 

along the guides until the whole card is separated from the chassis.

 

 

1) Direction of ejector lever 

2) Direction to pull out the RPU 

Figure 5-3

 

RPU removal

 

5.4.2  Install an RPU

 

Step 1: 

Power off the switch. (If there are two power modules installed, turn both of 

them off.

 

Step 2: 

Align the corners of the far edge with the guides in RPU slot and push the RPU 

inside the Eudemon200. At the same time, push the handles at both sides of the RPU 
inward until it well touches the RPU panel. (At this time, the corner between the RPU 
handle and its panel cannot be smaller.)

 

Step 3:

 Fasten the captive screws and fix the RPU on the Eudemon200. 

 

Step 4:

 Check if the fan status indicator on the RPU is normal after powering on the 

switch. For specific meanings, see “1.4.1 RPU”.

 

5.5  Replace an SDRAM

 

This section mainly introduces how to replace an SDRAM. See the following flow.

 

Summary of Contents for Quidway Eudemon 200

Page 1: ... 2 3 2 4 Installation Tools Meters and Equipment 2 5 Chapter 3 Installation 3 1 3 1 Installation Flow 3 1 3 2 Mount a Eudemon200 to a Specified Place 3 2 3 2 1 Mounting a Eudemon200 into the Rack 3 2 3 2 2 Mount a Eudemon200 onto the Workbench 3 3 3 3 Connect the PGND 3 3 3 4 Connect Power Cable 3 4 3 4 1 Connect AC Power Cable 3 4 3 4 2 Connect DC Input Power Cable 3 5 3 5 Connect the Console Ter...

Page 2: ...hapter 6 Troubleshooting 6 1 6 1 Troubleshooting of the Power System 6 1 6 2 Troubleshooting of the Configuration System 6 1 6 3 Troubleshooting of Application Software Upgrade 6 2 Chapter 7 Interface Module 7 1 7 1 Interface Module Category 7 1 7 2 Remove and Install Interface Module 7 1 7 3 Troubleshooting 7 2 7 4 1FE 2FE 7 3 7 4 1 Introduction 7 3 7 4 2 Interface Attributes 7 3 7 4 3 Panel and ...

Page 3: ...le 7 16 7 8 1ATM OC3MM 1ATM OC3SM 1ATM OC3SML 7 17 7 8 1 Introduction 7 17 7 8 2 Interface Attributes 7 18 7 8 3 Panel and Interface LED 7 18 7 8 4 Interface Optical Fiber 7 19 7 8 5 Connecting Interface Optical Fiber 7 20 Appendix A Specifications of Interface Cables A 1 A 1 Console Cable A 1 A 2 AUX Cable A 1 A 3 Ethernet Cable Pinouts A 2 A 3 1 RJ45 Connector A 2 A 3 2 Category 5 Twisted Pair A...

Page 4: ...HUAWEI Quidway Eudemon 200 Firewall Installation Manual ...

Page 5: ...ucts from the sales agent of Huawei Technologies Co Ltd please contact our sales agent If you purchase the products from Huawei Technologies Co Ltd directly Please feel free to contact our local office customer care center or company headquarters Huawei Technologies Co Ltd Address Administration Building Huawei Technologies Co Ltd Bantian Longgang District Shenzhen P R China Postal Code 518129 Web...

Page 6: ... Tellwin Inmedia VRP DOPRA iTELLIN HUAWEI OptiX C C08iNET NETENGINE OptiX iSite U SYS iMUSE OpenEye Lansway SmartAX infoX TopEng are trademarks of Huawei Technologies Co Ltd All other trademarks mentioned in this manual are the property of their respective holders Notice The information in this manual is subject to change without notice Every effort has been made in the preparation of this manual ...

Page 7: ...g started system management security defense VPN and QoS In addition it also provides the operation guide for the network interconnection Quidway Eudemon Series Firewall Command Manual It provides the commands of Eudemon Series firewalls such as management security defense upper layer service and network interconnection Organization of the Manual In Quidway Eudemon200 Firewall Installation Manual ...

Page 8: ...e Module Deals with the structure profile function interface indicator and connection cables of various network interface modules of Eudemon 200 Appendix Describes the internal connection of related cables Intended Readers The manual is intended for the following readers z Network engineers z Network administrators z Customers who are familiar with network fundamentals Conventions This document us...

Page 9: ...II Symbols Eye catching symbols are also used in this document to highlight the points worthy of special attention during the operation They are defined as follows Caution Warning Means reader be extremely careful during the operation Note Means a complementary description Environmental Protection This product has been designed to comply with the requirements on environmental protection For the pr...

Page 10: ...2 2 Safety Recommendations 2 3 2 3 Checking Eudemon200 and Accessories 2 3 2 4 Installation Tools Meters and Equipment 2 5 Chapter 3 Installation 3 1 3 1 Installation Flow 3 1 3 2 Mount a Eudemon200 to a Specified Place 3 2 3 2 1 Mounting a Eudemon200 into the Rack 3 2 3 2 2 Mount a Eudemon200 onto the Workbench 3 3 3 3 Connect the PGND 3 3 3 4 Connect Power Cable 3 4 3 4 1 Connect AC Power Cable ...

Page 11: ...move an RPU 5 3 5 4 2 Install an RPU 5 4 5 5 Replace SDRAM 5 4 Chapter 6 Troubleshooting 6 1 6 1 Troubleshooting of the Power System 6 1 6 2 Troubleshooting of the Configuration System 6 1 6 3 Troubleshooting of Application Software Upgrade 6 2 Chapter 7 Interface Module 7 1 7 1 Interface Module Category 7 1 7 2 Remove and Install Interface Module 7 1 7 3 Troubleshooting 7 2 7 4 1FE 2FE 7 3 7 4 1 ...

Page 12: ...ble 7 15 7 7 5 Connect Interface Cable 7 16 7 8 1ATM OC3MM 1ATM OC3SM 1ATM OC3SML 7 17 7 8 1 Introduction 7 17 7 8 2 Interface Attributes 7 18 7 8 3 Panel and Interface LED 7 18 7 8 4 Interface Optical Fiber 7 19 7 8 5 Connecting Interface Optical Fiber 7 20 Appendix A Specifications of Interface Cables A 1 A 1 Console Cable A 1 A 2 AUX Cable A 1 A 3 Ethernet Cable Pinouts A 2 A 3 1 RJ45 Connector...

Page 13: ...urity area The user can not only set as the predefined trust zone untrust zone or DMZ demilitarized zone but also can customize the areas at other security levels If the data is delivered between two interfaces at different security levels the security check function of the Eudemon200 firewall will be activated Following describes the features of the Eudemon200 firewall I Powerful attack defense c...

Page 14: ...itoring allows the Eudemon200 firewall to monitor the data traffic and connection status of the system and take appropriate measures when it discovers the abnormality so as to effectively prevent the network from being attacked by the malicious users The Eudemon200 firewall supports multiple traffic monitoring such as basic session monitoring committed access rate ISPKeeper function and real time ...

Page 15: ...ng their EMC and safety certification and network access requirements Besides the Eudemon200 firewall is designed in accordance with the UL CE and FCC standards meeting the safety certification requirements in China Europe and North America 2 Hot swappable dual power supplies 1 1 hot standby The Eudemon200 firewall uses dual power supply modules 1 1 backup and supports hot swap and AC DC input If ...

Page 16: ...Eudemon200 firewall The Eudemon200 firewall has three slots on the front panel with slot 0 for the RPU and slots 1 and 2 for interface modules Two power supply units PSU working in 1 1 backup mode can be horizontally installed in the Eudemon200 firewall from the rear of the chassis Both the AC input PSU and the DC input PSU are available and you may make selection as needed The fan module is locat...

Page 17: ...ure Long term 0 C 40 C Short term 5 95 non condensing Relative humidity Long term 5 85 non condensing Note SDRAM Synchronous Dynamic Random Access Memory is also known as the memory that stores the communication data between the system and CPU NVRAM Non Volatile Random Access Memory stores the abnormal alarm information Flash memory functions as the major file storage medium to store application p...

Page 18: ... console interface AUX interface and fixed Ethernet interface management packet transmitted and received processing and interface working status indication 4 Monitors power supply system status The Eudemon200 has two power modules RPU can initiatively query and obtain the abnormal information about power module to implement log and alarm indication 5 Monitors fan status Fan is a device that ensure...

Page 19: ...failed RUN green PWR2 PWR2 operation LED Constant ON means PWR2 is operating normally and constant OFF means PWR2 is no in place or has failed RPU System failure LED ON means CPU has received an alarm signal for PWR or FAN due to overheating for example FAN FAN failure LED ON means the FAN is no in place or its rotation is obstructed PWR1 PWR1 failure LED ON means PWR1 has failed ALM red PWR2 PWR2...

Page 20: ...al PC and run terminal emulation program on the PC Command Line Interface CLI 2 AUX interface Table 1 4 AUX interface attributes Attribute Description Connector RJ 45 Interface standard EIA TIA 232 Baud rate 300 115200bps Supported service Modem dialup Backup Serve as console port when the console port fails Supported protocol PPP 3 Ethernet interface The RPU provides two 10 100Base TX Ethernet po...

Page 21: ...nd the operating PWR will supply all the power required by the system The Eudemon200 firewall provides two types of PWRs i e AC input PWR and DC input PWR both providing the output power of 350W AC input PWR module uses PSR350 A power supply and each power module provides an output power of 350W The two way outputs are combined on the backplane DC input PWR module uses PSR350 D power supply and ea...

Page 22: ... Note If you want to install a Eudemon200 in a communication equipment room you should make sure that the power distribution cabinet can provide the lightning protection box or arrester against the current of 20KA and above II Appearance Figure 1 4 AC PWR Figure 1 5 DC PWR ...

Page 23: ... three groups When all these fans are working normally the operating temperature of the system can be maintained in the range of 0 to 55o C As the failure of a fan will not affect the operation of other fans the system will still be able to operate in the normal temperature The rotating speed of the fans is controlled by the RPU and is in the range of 50 to 100 The FAN controller uses two paramete...

Page 24: ...ode fiber interface card 1MFX z 1 port 100Base FX Ethernet single mode fiber interface card 1SFX z 4 port channelized T1 interface card 4T1 z 4 port channelized E1 interface card 4E1 z 1 port ATM 155M multi mode fiber interface card 1ATM OC3MM z 1 port ATM 155M single mode fiber interface card 1ATM OC3SM z 1 port ATM 155M single mode long distance fiber interface card 1ATM OC3SML For more informat...

Page 25: ...07 7 105 2 4 105 1 3 105 Gas SO2 H2S CI2 HCl HF NH3 O3 NO2 Average mg m3 0 3 0 1 0 1 0 1 0 01 1 0 0 05 0 5 Cleanness Gas Maximum mg m3 1 0 0 5 0 3 0 5 0 03 3 0 0 1 1 0 Long term operation Short term operation Temperatur es 0 C 40 C 5 C 50 C Temperatu re humidity Humidity 5 85 5 95 Note Short term operation means that the continuous working time does not exceed 72 hours and the accumulated time per...

Page 26: ... application system or from the inside will influence the equipment negatively in the conduction patterns of capacitance coupling inductance coupling electromagnetic wave radiation and common impedance including grounding system coupling To prevent the interference you should z Take effective measures against electricity network interference with the power supply system z Do not use the working gr...

Page 27: ...ecommendations When reading this manual you should pay adequate attention to the following symbol and the contents beneath it Caution appears throughout this manual in procedures that if performed incorrectly might harm you or damage the Eudemon200 firewall equipment When installing or working on a equipment you are recommended to z Keep the equipment far away from the heat sources and water liqui...

Page 28: ...module type and quantity when place an order 6 Power cord 1 2 PCS 7 PGND wire 1 PCS 8 Ethernet cable 2 PCS 8 core straight through cable 9 Console cable 1 PCS 10 AUX cable 1 PCS 11 Technology documentation 1 SET Include printed documentation Installation Manual for the equipment and CD ROM documentation 12 Installation mechanical part 1 SET 13 Product package 1 SET Include foam shockproof material...

Page 29: ...ti static bag z Phillips screwdriver P1 100MM with the power head type D76 2x5x60 Socket M6 flat screwdriver 4 75mm 2 Meters and equipment z Console terminal it could be a common PC z equipment related to the selected interface modules z Multimeter Caution The Eudemon200 firewall is not equipped with any installation tools meters or devices and the user has to prepare them ...

Page 30: ...the equipment Connect the equipment to the console terminal NO Install interface module Connect the equipment to Ethernet Connect the equipment to WAN End End Start the specified location Mount the cabinet optional Start Mount the equipment to Figure 3 1 Installation flow Caution Before installing a Eudemon200 firewall make sure that z You have read Chapter 2 Installation Preparation carefully z T...

Page 31: ...ght and its weight is 20kg with full configuration Take the following steps to mount a Eudemon200 firewall Step 1 Confirmation before mounting Ensure the rack has been well fixed The installation position for the Eudemon200 firewall has been well arranged and there is no obstacle inside the rack or around Ensure the equipment is ready for installation and has been carried to a place near the rack ...

Page 32: ... well grounded z Leave the clearance of 10cm around the Eudemon200 for heat dissipation z Never put heavy things on the Eudemon200 3 3 Connect the PGND Warning The normal connection of PGND wire for the Eudemon200 firewall is the essential safeguard against the lightning shocks and interference Therefore you must first correctly connect the PGND wire when installing and using the Eudemon200 The Eu...

Page 33: ... ground screw to the earth ground using a PGND cable requiring a grounding resistance less than 5 ohm If you install the Eudemon200 in a 19 inch standard rack you must also ground the rack 3 4 Connect Power Cable The Eudemon200 firewall has AC input and DC input power supply modules available You can make your selection as needed These modules have the same features and functions except for PWR ty...

Page 34: ...cord III Connect AC Power cable Step 1 Check that the PGND wire has been correctly connected to the ground Step 2 Place the power switch of the Eudemon200 firewall to the OFF position insert one end of the power cord accompanying the Eudemon200 into the power socket on the Eudemon200 s rear panel fix the cable onto the cable retention clip with a cable strap and connect the other end of the cable ...

Page 35: ... blue 48V lead X1 A1 X3 black BGND lead X1 A3 Step 1 Check that the PGND wire has been correctly connected to the ground Step 2 Make sure that the power switch of the Eudemon200 firewall is in the OFF position and connect one end of the DC power cable to the power socket on the rear panel of the equipment chassis and the other end to the 48V DC power supply Warning In order to prevent from wrong c...

Page 36: ...ole cable Console cable is an 8 core shielded cable At one end of the cable is a crimped RJ 45 connector that is to be plugged into the console port of the Eudemon200 firewall At the other end of the cable are a DB 9 female connector and a DB 25 female connector You can plug either of them into the serial port on the console terminal as needed The following figure illustrates the console cable Enl...

Page 37: ...200 firewall provide the fixed 10 100Base TX FE interface For details of its attributes refer to the section 1 4 1 RPU II Ethernet cable 10 100Base TX Ethernet interface usually adopts the category 5 twisted pair for connection as shown in the following figure Figure 3 9 Ethernet cable Ethernet cables fall into two categories i e straight through cables and crossover cables z Straight through cabl...

Page 38: ...Choose the Ethernet cable z Use a crossover cable to connect the Eudemon200 firewall to a PC by connecting one end of the cable to the Ethernet port on the Eudemon200 and the other end to the PC z Use a straight through cable to connect the Eudemon200 to a HUB or LAN Switch by connecting one end of the cable to the Ethernet port on the Eudemon200 and the other end to the HUB or the LAN Switch Step...

Page 39: ...ug either of them into the serial port of Modem as needed The following figure illustrates the AUX cable E n la r g e d A s id e P o s 1 A P os 2 5 D B 2 5 M a le L a b e l 8 P 8 C P L U G B P o s 1 P o s 8 E n la r g e d B s id e D B 9 M a le E nl ar g ed C s id e P o s 9 P o s 1 C Figure 3 10 AUX cable For the pinouts of AUX cable please refer to Appendix A III Connect the AUX cable Follow these...

Page 40: ...udemon200 firewall for adequate dissipation and the cabinet is stable enough z The correct power supply is used z The connection of the PGND wire of the Eudemon200 firewall is correct and secure z The connections with other devices such as the console terminal are correct Note It is very important for you to check the equipment installation as the secure connection well grounding and use of the co...

Page 41: ...200 firewall and DB 25 connector or DB 9 connector to the serial interface of a PC as shown in Figure 4 1 RS232 Serial Console cable Console port Eudemon200 Figure 4 1 Local configuration through Console port II Set the parameters of configuration terminal Step 1 Start the terminal and set up a new connection If the configuration is performed through a PC the terminal emulation program such as Ter...

Page 42: ...onfiguration choose the serial interface to be connected in the Connect Using box as shown in Figure 4 3 Please notice that the selected serial interface should be consistent with the actual serial interface connected by the console cable Figure 4 3 Setting the connection port in the local configuration 2 Configure the serial interface parameter settings As shown in Figure 4 4 in the properties di...

Page 43: ...one Click the OK button to return to the HyperTerminal interface Figure 4 4 Setting serial interface parameters 3 Set HyperTerminal properties Select Property Settings on the HyperTerminal and enter the property setting window as shown in Figure 4 55 Select VT100 or auto detection as terminal simulation type press Ok and return to the HyperTerminal window ...

Page 44: ...her the power cord and ground wire are correctly connected z Whether the voltage of the power supply complies with the requirement of the Eudemon200 firewall z Whether the console cable is correctly connected whether the PC or terminal for configuration is started and whether the settings are done Warning Before switching on the power locate the power switch in the equipment room so that in case o...

Page 45: ...elf test POST is done press Enter After the command line prompts Eudemon you can start configuration 4 1 3 Startup Process I Self test on SDRAM During the process of powering on the Eudemon200 firewall or resetting the Eudemon200 the configuration terminal yields the following output first Do you want to go on checking sdram Yes or not Y N This information asks if you want to check the SDRAM If yo...

Page 46: ... take the next step Note The system provides BootROM master system automatic updating function Before executing an application if it finds the BootROM master system version is different from that recorded in the BootROM chip it will automatically update the BootROM master system and reset it The following information will display Update Bootrom done system will reboot III Select booting device and...

Page 47: ...guration interface and start configuring the Eudemon200 After you press Enter the terminal screen displays the following information Eudemon 4 2 Configuration Fundamentals 4 2 1 Basic Configuration Procedure In general the configuration steps are as follows Step 1 Before configuring a Eudemon200 firewall the networking requirements have to be made specific and detail They include networking purpos...

Page 48: ... user can configure and manage the Eudemon200 firewall The command line interface has the following features z Performs the local configuration through Console port z Performs the local or remote configuration through the Telnet command which can be used to directly log on and manage other Eudemon200 firewalls z Users can enter at any time to get online help z Provide prompt and help information f...

Page 49: ...umber or is fixed as 0 when there is no pinch board and Z specifies the interface sequence number z As shown in the above figure different interfaces of an interface module share the same slot number X z Each interface sequence number Z starts with 0 and arranges according to the interface module sequence number from left to right For example 1FE and 2FE modules are installed in Slot1 and Slot2 of...

Page 50: ...hich includes the first time start the upload download and software upgrading of the Eudemon200 refer to Operation Manual Caution Do not upgrade the Eudemon200 firewall software at will If the upgrade is necessary it is recommended to perform it under the guidance of the technical support personnel ...

Page 51: ...hnical support personnel z Remember to wear ESD preventive wrist strap and make it well contact with your skin z For the device to operate normally use the SDRAM provided by Huawei Technologies Co Ltd only 5 1 Tools Required z Phillips screwdriver P1 100MM z The power head of the screwdriver can be D76 2X5X60 z ESD preventive wrist strap and ESD preventive glove z Static shielding bag 5 2 Power Mo...

Page 52: ... power panel inside the power slot of the chassis Step 2 Fasten the two captive screws in the power module panel Step 3 Check if the power switch on the panel is ON Step 4 Plug one end of the power cord shipped with the chassis into the socket in the power module and connect the other end to the power supply Step 5 Check if the power status indicator on the RPU is normal For specific meanings see ...

Page 53: ... while for the sake of inertia Be careful and do not put your finger into the rotating fan z The fan is rather long Use one hand to hold the bottom of the fan and the other hand to hold the handle attached to the front of the fan in order to pull it out slowly Figure 5 2 Fan removal 5 3 2 Install a Fan Step 1 Hold the handle attached to the front of the fan with one hand and hold the bottom with t...

Page 54: ...PU Figure 5 3 RPU removal 5 4 2 Install an RPU Step 1 Power off the switch If there are two power modules installed turn both of them off Step 2 Align the corners of the far edge with the guides in RPU slot and push the RPU inside the Eudemon200 At the same time push the handles at both sides of the RPU inward until it well touches the RPU panel At this time the corner between the RPU handle and i...

Page 55: ...r upgrades the application program z The SDRAM capacity needs to be increased because the route table is too large to be maintained by the Eudemon200 firewall or other applications consume large memory z The existing SDRAM is damaged Caution z Do not touch the component on the surface of the SDRAM with bare hand You can only take it at the non conductive edge You can only hold it by the non conduc...

Page 56: ...RAM into an anti static bag to avoid ESD damage III Install an SDRAM Step 1 Take out a new SDRAM Hold the SDRAM by its top non conductive edge and put it into an SDRAM slot in correct direction Step 2 Exercise adequate pressure on the SDRAM and press it into the slot and press the locking clip at both sides of the slot When the force is appropriate the locking clips will shut and the bumps at both...

Page 57: ... AC 90 264V DC 36 72V off means the input voltage is abnormal Caution Do not plug unplug the power cord when the power is ON After having checked the items above if the POWER LED is still OFF contact the agent 6 2 Troubleshooting of the Configuration System After the Power On Self Test POST of the Eudemon200 if the system operates normally the start up information should be displayed on the consol...

Page 58: ...the console terminal displays illegible characters 2 Troubleshooting Verify whether the terminal e g the HyperTerminal parameter settings are as follows Baud 9600 Data bits 8 Stop bit 1 Parity None Flow control None Terminal emulation VT100 If the parameter settings do not match the above values reconfigure them 6 3 Troubleshooting of Application Software Upgrade I Upgrade boot device error 1 Faul...

Page 59: ... 1 1 host inet h 1 1 1 2 user u user ftp password pw password flags f 0x80 Attached TCP IP interface to wancom0 Subnet Mask 0xffffffc0 Attaching network interface lo0 done Loading Error code 2 Access violation tftpGet Error occurred while transferring the file A bad file or twisted pair doesn t link correctly Loading Failed 2 Troubleshooting The problem occurs because the file to be downloaded doe...

Page 60: ... 1 1 1 host inet h 1 1 1 2 user u user ftp password pw password flags f 0x80 Loading Done 1000 Bytes Downloaded Crc Error 2 Troubleshooting The problem occurs because the downloaded file is incorrect Note You can find bar code labels containing the information of product and maintenance on the Eudemon200 chassis and FIC If you want to have the device maintained feed the bar code of the faulty devi...

Page 61: ... 11 2FE 1MFX 1 port 100Base FX Ethernet multi mode fiber interface module FW 11 1MFX Ethernet interface modules 1SFX 1 port 100Base FX Ethernet single mode fiber interface module FW 11 1SFX 4T1 4 port channelized T1 interface module FW 11 4T1 4E1 4 port channelized E1 interface module FW 11 4E1 1ATM OC 3MM 1 port ATM 155M multi mode fiber interface module FW 11 1ATM OC3MM 1ATM OC 3SM 1 port ATM 15...

Page 62: ...forward Step 2 Remove the cables connected to the interface module Step 3 Loosen the captive screws at both sides of the interface module Step 4 Pull the ejector levers at both sides of the interface module outward pull the interface module out of the slot along the guides until disengaging it totally from the slot III Install Interface Module Step 1 Place the Eudemon200 with the front panel forwa...

Page 63: ...e for Eudemon200 are primarily used for the communications between the Eudemon200 and LAN s Following are the differences between 1FE and 2FE z 1FE provides one 10 100Mbps RJ 45 Ethernet interface z 2FE provides two 10 100Mbps RJ 45 Ethernet interfaces The FE cards support z The transmission distance of 100 meters if the category 5 twisted pairs are used z The operation at the speeds of 100Mbps an...

Page 64: ...nterface Cable As shown in Figure 7 1 Ethernet cable of FE cards is a category 5 twisted pair with RJ 45 connectors Pins 1 and 2 of the interface are at the transmitting terminal and Pins 3 and 6 are at the receiving terminal Figure 7 1 Ethernet cable Ethernet cables fit into two categories i e straight through cables and crossover cables z Straight through cable The sequences of the twisted pairs...

Page 65: ...one end of the cable into an Ethernet port on the FE card and another end to a HUB or LAN Switch Step 2 Power on the firewall and check the status of the LINK LED on the FE panel ON means that the link has been connected and OFF means that the link is not connected In the latter case check the line Caution You must connect a cable to the interface with the appropriate mark Misplugging is prone to ...

Page 66: ...in phase difference and hence limiting the transmission band In terms of fiber core diameter there are two types of multi mode optical fibers i e 62 5µm and 50µm which are acceptable transmission media in ISO IEC 11801 standard 7 5 2 Interface Attributes Table 7 4 1MFX 1SFX interface attributes Description Attribute 1SFX 1MFX Connector SC Connector number 1 Optical fiber mode Single mode Multi mod...

Page 67: ... not connected and ON means the link is connected ACT OFF means no data is being transceived on the interface and blinking means data is being transceived 7 5 4 Interface Optical Fiber 1MFX should be connected to multi mode optical fiber and 1SFX to single mode optical fiber The optical interfaces of both cards are SC optical receptacles so the optical fibers with SC connector should be selected F...

Page 68: ...quare transceiving optical fiber connector Note The two types of optical fibers are optional and you need to select the desired fibers when purchasing 1MFX and 1SFX otherwise they are not provided 7 5 5 Connect Interface Optical Fiber Warning Laser Danger Do not observe the optical fiber connector connected with the laser in case the invisible laser radiation harms your eyes Caution When connectin...

Page 69: ...ot only supports FE1 mode which can form only a bundle In other words the time slots can only be bundled into one channel at the speed of nx64K given n 1 31 but also a 4E1 module supports channelized E1 CE1 mode and PRI mode 7 6 2 Interface Attributes Table 7 6 describes the interface attributes of 4E1 Table 7 6 Interface attributes of 4E1 Description Attribute 4E1 Connector DB 25 Connector number...

Page 70: ...des two types of 1 to 4 adapter cables that is 120 ohm 4E1 adapter cable and 75 ohm 4E1 adapter cable At one end of both these two types of cables is the DB 25 connector used for connecting the Eudemon200 and at the other end are four DB 15 connectors used for connecting E1 cables You can distinguish these two types of cables by the main labels The identifier printed on the main label of 120 ohm 4...

Page 71: ...tion Manual Quidway Eudemon 200 Firewall Chapter 7 Interface Module 7 11 H U A WE I H U A WE I H UA WE I H U A WE I DB25 male DB15 female Figure 7 3 120 ohm 4E1 adapter cable Figure 7 4 75 ohm 4E1 adapter cable ...

Page 72: ...rs 7 6 5 Internal DIP Switch 4E1 provides internal DIP switches the setting of which decides the interface impedance and the grounding mode Table 7 8 DIP switches and E1 interfaces of 4E1 Module 4E1 DIP switch S1 S2 S3 S4 The controlled E1 interface Interface 0 Interface 1 Interface 2 Interface 3 By default all the DIP switches for 4E1 are placed to the position of ON as illustrated in Figure 7 5 ...

Page 73: ...FF RxShield is not grounded 8BIT RxShield grounding mode selection switch OFF RxShield is grounded via capacitance ON RxShield is grounded directly Caution z So far as the 4E1 are concerned you are recommended to place the DIP switches BITs 1 through 8 to the ON position when connecting the modules to external 75 ohm cables and BITs 1 through 8 to the OFF position when connecting the modules to ex...

Page 74: ... port is 120 ohm select the E1 120 ohm balanced twisted pair cable and 120 ohm 4E1 adapter cable and set all the DIP switches on 4E1 to the OFF position that is the port impedance is 120 ohm Step 2 Insert the DB 25 connector of the 4E1 adapter cable into the desired DB 25 port on 4E1 port and tighten the thumbscrews Step 3 Determine the sequence number of the DB 15 connector at the other end of th...

Page 75: ...ted service Backup Terminal access service Supported protocol PPP MP 7 7 3 Panel and Interface LED Table 7 11 illustrates the 4T1 panels and LEDs description Table 7 11 4T1 panels and LEDs description Name Panel figure 4T1 Category Flash state and description LINK OFF means the link is not connected and ON means the link is connected ACT OFF means no data is being transceived on the interface and ...

Page 76: ...on z You must connect a cable to the interface with the appropriate mark Misplugging is prone to impair the interface module and even damage the interface module mainframe z In the event that the T1 cable is led outdoors you are recommended to install a special lightning arrester at the input end of the T1 cable for the purpose of achieving a better lightning protection effect Step 1 Insert one en...

Page 77: ...he line in this case 7 8 1ATM OC3MM 1ATM OC3SM 1ATM OC3SML 7 8 1 Introduction ATM interface modules including 1ATM OC3MM 1ATM OC3SM and 1ATM OC3SML function in the system primarily to provide ATM interfaces for the Eudemon200 They can z Support two frame formats namely SDH STM 1 and SONET OC 3 z Allow scrambling in data transmission z Support both line clock used when working as DTE interface and ...

Page 78: ...smission distance Single mode optical fiber of 30km transmission distance Transmitter LED LD LD Transmitting optical power Min 15dBm Max 8dBm Min 19dBm Max 14dBm Min 5dBm Max 0dBm Receiver sensitivity Min 28dBm Max 8dBm Min 30dBm Max 14dBm Min 34dBm Max 10dBm Central wavelength 1310nm Supported service ATM Traffic CBR Constant Bit Rate rt_VBR Variable Bit Rate Real Time nrt_VBR Variable Bit Rate N...

Page 79: ...s no data is being transceived on the interface and blinking means data is being transceived 7 8 4 Interface Optical Fiber 1ATM OC3MM uses multi mode optical fibers and 1ATM OC3SM 1ATM OC3SML use single mode optical fibers As all these three interface modules adopt SC optical fiber connectors the connectors of the optical fibers must also be SC connectors The external optical cable suite provides ...

Page 80: ...fibers are optional User should select corresponding fibers before purchasing 1ATM OC3MM 1ATM OC3SM or 1ATM OC3SML card 7 8 5 Connecting Interface Optical Fiber Warning When connecting the fiber optic pay attention to the following z Do not bend the fiber optic overly z Ensure TX and RX end of the interface are proper connected z Ensure the cleanness at the interface of the fiber optic Warning Las...

Page 81: ...stance fiber interface requiring a transmission at least longer than 25km If the transmission distance is lower than 25km the interface will be unable to receive signals z 1ATM OC3MM should be connected with multi mode optical fibers whereas 1ATM OC3SM 1ATM OC3SML should be connected with single mode optical fibers ...

Page 82: ...described in the following tables of this appendix are not connected A 1 Console Cable Table A 1 Console cable pinouts RJ45 Signal Direction DB25 DB9 Signal 1 5 8 CTS 2 6 6 DSR 3 3 2 RXD 4 8 1 DCD 5 7 5 GND 6 2 3 TXD 7 20 4 DTR 8 4 7 RTS A 2 AUX Cable Table A 2 AUX cable pinouts RJ45 Signal Direction DB25 DB9 Signal 1 4 7 RTS 2 20 4 DTR 3 2 3 TXD 4 8 1 DCD 5 7 5 GND ...

Page 83: ...ted Pair Category 5 twisted pair comprises 8 core copper wires The copper wires can be identified and grouped according to the colors of their outer insulation layers Usually one pair consists of one wire in color A referring to a pure color and the other one in a mixed color of A and white Sometimes paired color points are also used as identification colors The Category 5 twisted pairs mentioned ...

Page 84: ...A 3 3 Ethernet Cable Pinouts Table A 3 Straight through cable pinouts RJ45 Signal Category 5 Twisted Pair Signal Direction RJ45 1 TX White Orange 1 2 TX Orange 2 3 RX White Green 3 4 Blue 4 5 White Blue 5 6 RX Green 6 7 White Brown 7 8 Brown 8 Table A 4 Crossover cable pinouts RJ45 Signal Direction Category 5 Twisted Pair Signal Direction RJ45 1 TX White Orange 3 2 TX Orange 6 3 RX White Green 1 4...

Page 85: ... cables While preparing the Ethernet cables please follow the chromatogram given in the table above to arrange the wires Otherwise communication quality will be affected even though the equipment at two ends are connected A 4 E1 Cable and 4E1 Conversion Cable Table A 5 E1 cable pinouts DB15 BNC 75 ohm coaxial cable RJ 45 120 ohm twisted pair 9 Tx Tip Tx Tip 1 Tx Tip 2 Tx Ring Tx Ring 2 Tx Ring 10 ...

Page 86: ...g 4 5 TxR3 2 TxRing 19 RxSD3 7 RxShield 17 RxT3 8 RxTip 4 TxT3 9 TxTip 6 TxSD3 10 TxShield 18 RxR3 15 RxRing 3 9 TxR2 2 TxRing 22 RxSD2 7 RxShield 20 RxT2 8 RxTip 8 TxT2 9 TxTip 10 TxSD2 10 TxShield 21 RxR2 15 RxRing 2 12 TxR1 2 TxRing 25 RxSD1 7 RxShield 23 RxT1 8 RxTip 11 TxT1 9 TxTip 13 TxSD1 10 TxShield 24 RxR1 15 RxRing 1 Note Tx transmit Rx receive Rx and Tx marked on 75 ohm coaxial cable ar...

Page 87: ...ions of Interface Cables A 6 A 5 T1 Cable Table A 7 T1 cable pinouts RJ45 Straight through Shielded Network Cable Signal Description RJ45 1 White Orange Rx Ring 1 2 Orange Rx Tip 2 3 White Green 3 4 Blue Tx Ring 4 5 White Blue Tx Tip 5 6 Green 6 7 White Brown 7 8 Brown 8 ...

Reviews: