HUAWEI RP Series Telepresence Systems
V100R001C04 Commissioning Guide
2 Deployment Preparation
Issue 01
Huawei Confidential
17
Type
Description
Part
Number
Quantity Remarks
Network
cable
RJ45-RJ45 cable 04046011
1
-
Power
cable
Chinese-standard
power cable
04041104
1
-
1 m power cable
04050206
2
-
HD display
power cable
04043491
2
One piece is provided with an
RP100 system.
5-socket PDU
14190404
1
-
2.5 Powering Devices On
After unpacking cartons, check whether any devices are dead on arrival (D.O.A). If any
D.O.A device is found, protect the site and take a picture for the record and immediately
contact the supply chain personnel. Table 2-8 describes the devices need to be powered on for
inspection and their qualification criteria.
Table 2-8
Devices to be powered on
Device
Qualification Criteria
HD display
The HD displays are powered on properly, and HDMI and VGA video
sources are displayed without artifacts.
HD
videoconferencing
endpoint
The remote control UI of the videoconferencing endpoint is displayed
on the HD display.
HD camera
The images collected by the HD camera are displayed on the HD
display.
2.6 Setting IP Addresses for the HD Videoconferencing
Endpoints
Step 1
Connect a computer directly to the HD videoconferencing endpoint whose IP address needs to
be modified. Change the computer's IP address to be in the same network segment as that of
the videoconferencing endpoint's default IP address
192.168.1.1
.