Parameter
Description
Maximum grid
feed-in power
(kW)
N/A
Specifies the maximum active power
transmitted from the grid-tied point
to the power grid.
Power
adjustment
period
N/A
Specifies the shortest interval for a
single export limitation adjustment.
Maximum
protection time
N/A
● Specifies the time for detecting
power meter data. If the Smart
Dongle does not detect any power
meter data within the preset time,
the Smart Dongle delivers the
preset value of the Fail-safe
power threshold to the inverter
for protection.
● The recommended value is 5s or
greater.
Power control
hysteresis
N/A
Specifies the dead zone for adjusting
the inverter output power. If the
power fluctuates within the power
control hysteresis, the power is not
adjusted.
Fail-safe power
threshold
N/A
Specifies the derating value of the
inverter active power by percentage.
If the Smart Dongle does not detect
any power meter data or the
communication between the Smart
Dongle and the inverter is
disconnected, the Smart Dongle
delivers the derating value of the
inverter active power by percentage.
Grid
connection
with limited
power (%)
Closed-loop
controller
● SDongle/
SmartLogger
● Inverter
● For a single inverter: When the
Smart Dongle is connected, set
Closed-loop controller to
Inverter. When the inverter is
directly connected, Closed-loop
controller to Inverter. When the
SmartLogger is connected, set
Closed-loop controller to
SDongle/SmartLogger.
● For multiple inverters, Closed-
loop controller can only be set to
SDongle/SmartLogger.
FusionSolar Smart PV Management System
Connection
User Manual (Inv SDongleA)
5 Site Deployment and Commissioning
Issue 02 (2021-11-25)
Copyright © Huawei Technologies Co., Ltd.
45