SUN2000-(30KTL-A, 33KTL, 40KTL)
User Manual
2 Overview
Issue 04 (2016-06-20)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
8
Indicator
Status
Meaning
Off
The inverter has not received
data over RS485/PLC
communication for 10 seconds.
Alarm/Maintenance
indicator
Alarm state
Blinking red
slowly (on for
1s and then off
for 4s)
The SUN2000 has generated a
warning.
Blinking red
fast (on for
0.5s and then
off for 0.5s)
The SUN2000 has generated a
minor alarm.
Steady red
The SUN2000 has generated a
critical alarm.
Local
maintenance
state
Blinking green
slowly (on for
1s and then off
for 1s)
Local maintenance is in
progress.
Blinking green
fast (on for
0.125s and off
for 0.125s)
Local maintenance has failed.
Steady green
Local maintenance is successful.
Local maintenance refers to operations performed after a universal serial bus (USB) flash drive,
Bluetooth module, or USB data cable is inserted into the USB port of the SUN2000. For example,
local maintenance includes data import and export using a USB flash drive and connecting to the
SUN2000 APP over a Bluetooth module or USB data cable.
If alarming and local maintenance happen concurrently, the alarm/maintenance indicator shows the
local maintenance state first. After the USB flash drive, Bluetooth module, or USB data cable is
removed, the indicator shows the alarm state.
Rear View
Figure 2-7
shows the SUN2000 rear view.