SUN2000-(30KTL-A, 33KTL, 40KTL)
User Manual
5 Electrical Connections
Issue 04 (2016-06-20)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
54
Highly rigid cables, such as armored cables, are not recommended because bending may
cause poor contact.
Positive and negative connectors
DC input connectors are categorized into positive and negative connectors, as shown in
Figure 5-16
and
Figure 5-17
.
Figure 5-16
Positive connector composition
(1) Insulation shell
(2) Locking nut
Figure 5-17
Negative connector composition
(1) Insulation shell
(2) Locking nut
Use the Amphenol HH4 DC input terminals delivered with the SUN2000. If the terminals
are lost or damaged, prepare Amphenol HH4, Amphenol H4, or MC4 DC input terminals
by yourself. You can also purchase Amphenol HH4 DC input terminals from Huawei.
DC input terminals not of the previous models may be incompatible with the SUN2000,
which may cause serious consequences. The caused equipment damage is beyond the
warranty scope.
Positive and negative metal terminals are packed with positive and negative connectors respectively.
After unpacking, keep the positive and negative ones separate to avoid confusion.