No.
Parameter
Description
Remarks
3
PQ mode
If this parameter is set to PQ mode 1,
the maximum active power equals the
maximum apparent power. If it is set to
PQ mode 2, the maximum active power
equals the rated active power.
4
Auto start upon
grid recovery
Specifies whether to allow the SUN2000
to automatically start after the power
grid recovers.
N/A
5
Grid connection
duration after
power grid
recovery
Specifies the waiting time for SUN2000
restart after the power grid recovers.
N/A
6
Grid reconnection
voltage upper
limit
The standards of certain countries and
regions require that the SUN2000 must
not export power to the power grid
again when the grid voltage exceeds the
value of Grid reconnection voltage
upper limit after the SUN2000 shuts
down due to a fault.
N/A
7
Grid reconnection
voltage lower limit
The standards of certain countries and
regions require that the SUN2000 must
not export power to the power grid
again when the grid voltage is below the
value of Grid reconnection voltage
lower limit after the SUN2000 shuts
down due to a fault.
N/A
8
Grid reconnection
frequency upper
limit
The standards of certain countries and
regions require that the SUN2000 must
not export power to the power grid
again when the grid frequency exceeds
the value of Grid reconnection
frequency upper limit after the
SUN2000 shuts down due to a fault.
N/A
9
Grid reconnection
frequency lower
limit
The standards of certain countries and
regions require that the SUN2000 must
not export power to the power grid
again when the grid frequency is below
the value of Grid reconnection
frequency lower limit after the
SUN2000 shuts down due to a fault.
N/A
10
Reactive power
compensation
(cosφ-P) trigger
voltage
Specifies the voltage threshold for
triggering reactive power compensation
based on the cosφ-P curve.
N/A
SUN2000-(50KTL, 60KTL, 65KTL)-M0
User Manual
7 Man-Machine Interactions
Issue 06 (2020-07-07)
Copyright © Huawei Technologies Co., Ltd.
85