SUN2000-(55KTL, 60KTL) Series
User Manual
7 Man-Machine Interactions
Issue 02 (2017-07-30)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
75
No. Parameter Description
Unit
Default
Value
Value Range
Remarks
input power
greatly
decreases.
If
PV module
type
is set to
CPV 2
, the
SUN2000 can
restart quickly in
10 minutes if PV
modules are
shaded and the
input power
greatly
decreases.
7
Crystalline
silicon PV
compensati
on mode
This parameter
reduces the DC
voltage of PV modules
to the PE by reducing
the impedance of the
SUN2000 input side to
the PE, thereby
effectively reducing
PID effect of PV
modules.
N/A
Output
disabled
Output
disabled
P-type output
N-type
output
This parameter is
displayed if
PV
module type
is set
to
Crystalline
silicon
. Set this
parameter to
P-type
output
for P-type
PV modules and
N-type output
for
N-type PV modules.
8
Communic
ation
interrupt
shutdown
The standards of
certain countries and
regions require that
the SUN2000 must
shut down after the
communication is
interrupted for a
certain time.
N/A
Disable
Disable
Enable
If
Communication
interrupt
shutdown
is set to
Enable
and the
SUN2000
communication has
been interrupted for
a specified time (set
by
Communication
interruption
duration
), the
SUN2000 will
automatically shut
down.
9
Communic
ation
interruptio
n duration
Specifies the duration
for determining
communication
interruption, and is
used for automatic
shutdown for
protection in case of
communication
interruption.
min
30
[1, 120]
N/A
10
Communic
ation
If this parameter is
enabled, the SUN2000
N/A
Enable
Disable
N/A