SUN2000-(55KTL, 60KTL) Series
User Manual
7 Man-Machine Interactions
Issue 02 (2017-07-30)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
76
No. Parameter Description
Unit
Default
Value
Value Range
Remarks
resumed
startup
automatically starts
after communication
recovers. If this
parameter is disabled,
the SUN2000 needs to
be started manually
after communication
recovers.
Enable
11
Soft start
time
Specifies the duration
for the power to
gradually increase
when the SUN2000
starts.
s
The default
value varies
depending
on the grid
code. The
displayed
value
prevails.
[20, 1800]
N/A
12
Current
error
during
scanning
When the IV curves of
PV strings are being
scanned, the current
change of PV strings
operating properly
should be monitored
to avoid inaccurate
scanning caused by
sunlight change. If the
current exceeds the
specified value, it is
determined that the
sunlight changes, and
the IV curves should
be scanned again.
A
0.20
[0.00, 2.00]
N/A
13
Hibernate
at night
The SUN2000
monitors PV strings at
night. If
Hibernate at
night
is set to
Enable
,
the monitoring
function of the
SUN2000 will
hibernate at night,
reducing power
consumption.
N/A
Disable
Disable
Enable
N/A
14
PLC
communica
tion
For SUN2000 models
that support both
RS485 and PLC
communication, when
RS485 communication
is used, you are
advised to set
PLC
communication
to
N/A
Enable
Disable
Enable
N/A