SUN2000L-(2KTL-5KTL)
User Manual
7 Operations on the Local FusionHome App
Issue 02 (2017-12-12)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
80
----End
Forced Charge/Discharge
Step 1
On the
Operation console
screen, choose
Device maintenance
>
Energy control
>
Energy
storage control
>
Forced charge/discharge
and perform the corresponding operation.
Figure 7-27
Forced charge/discharge
Table 7-5
Description of forced charge/discharge parameters
Parameter
Description
Value Range
Charge/discharge power
Specifies the forced
charge/discharge control
mode.
Stop
Charge power
Discharge power
Forcible chg/dis pwr (W)
Specifies the forced
charge/discharge power.
[Negative maximum
discharge power, maximum
charge power]
Forcible chg/dis time (mins)
Specifies the forced
charge/discharge duration.
[0, 1440]
Remaining charge/discharge
time (mins)
Displays the remaining
charge/discharge time. This
Parameter cannot be set.
[0, 1440]
----End