3.7 Setting Network Diagnostics Parameters
Correct settings for network diagnostics parameters enable you to employ a network diagnostics
tool to diagnose your TE30 using ports.
Procedure
Step 1
Choose
Advanced Settings
>
Settings
>
Network
>
Diagnostics
. Set the network diagnostics
parameters by referring to
Table 3-7
Network diagnostics parameters
Parameter
Description
Setting
Network
diagnostics
Specifies whether to enable the H.323 call
port, RAS ports, and SIP call port to be
used for network diagnostics. If you select
this parameter, you must also set
H.323
call port
,
RAS source port
,
RAS
destination port
, and
SIP call port
.
This parameter is deselected by
default.
H.323 call
port
Specifies the port the network diagnostics
tool uses to send and receive call signaling
during communication with your TE30.
The default value is
1820
.
RAS source
port
Specifies the port your TE30 uses to send
and receive RAS signaling during
communication with the network
diagnostics tool.
The default value is
1819
.
RAS
destination
port
Specifies the port the network diagnostics
tool uses to send and receive RAS
signaling during communication with
your TE30.
The default value is
1819
.
SIP call port
Specifies the port your TE30 uses to send
SIP signaling during communication with
the network diagnostics tool.
The default value is
5160
.
Test network
after exiting
conference
Specifies whether to perform a ping test
after your TE30 exits a conference. Ping
results are recorded in logs.
The default value is
Enable
.
Step 2
Select
Save
.
----End
HUAWEI TE30 Videoconferencing Endpoint
User Guide
3 Network
Issue 01 (2013-03-27)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
27